PCZ1000A
3-25
3
Ope
ration
Procedure for Setting Master and Slave Units
1
Turn on the POWER switch on each unit.
Either turn on the POWER switch on all units at the same time or turn on the master
unit first.
• If the power to the slaves is turned on first, turn on the POWER switch on the
master unit within 30 seconds of turning on the POWER switch on the slaves.
An external alarm 2 occurs if this time is longer than 30 seconds.
2
Press the LOAD key to go to the load-off state.
3
Press SHIFT + I SET(CONFIG).
4
Press the ENTER key to select ">1:Norm /M/S".
5
Use the rotary knob to select "MASTER" or "SLAVE".
6
Use the ENTER key to select ">2: Para/Track".
7
Use the rotary knob to select "PARALLEL".
Selecting "PARALLEL" for parallel operation causes the total current from the master
and slave units to be displayed on the ammeter display of the master unit.
8
On a slave unit, press the SHIFT+I SET (CONFIG) key or press the
ESC key to exit CONFIG setting. On the master unit, proceed to the
next step.
On the slave units, "P <<Slave>>" appears on the front panel display.
9
Press the ENTER key to select ">3:Parallel Ope.".
> 1: Norm/M/S
MASTER
> 2: Para/Track
PARALLEL
P << Slave >>
Summary of Contents for PCZ1000A
Page 4: ...ii PCZ1000A This page is intentionally blank ...
Page 17: ...General Description This chapter gives an overview and describes the features of the PCZ1000A ...
Page 35: ...Operation This chapter describes each mode and function of the operation ...
Page 82: ...5 4 PCZ1000A This page is intentionally blank ...
Page 83: ...Specifications This chapter gives the specifications and dimensions of the PCZ1000A ...
Page 88: ...6 6 PCZ1000A This page is intentionally blank ...
Page 89: ...The appendix contains the basic operating modes operating range and troubleshooting Appendix ...
Page 99: ......