3-16
PCZ1000A
3.5.4
Crest Factor Function
The Crest Factor function simulates the current waveform of a capacitive input
rectified load.
Fig.3-6 shows the front panel display of the crest factor setting. The input terminal
measurements are displayed on the upper side.
Fig.3-6
Crest Factor Setting Display
1
If the LED above the LOAD key is on, press the LOAD key to change to
load-off.
2
Press the I SET key to enable CC mode.
The C.C LED at the top of the panel illuminates.
3
Press the SHIFT + C.F key to enable the crest factor function.
The LED above the C.F key illuminates.
4
Pressing the C.F key again allows the crest factor setting to be
specified (the existing setting appears in the lower part of the display).
"CREST FACTOR" appears in the lower part of the display.
5
Use the rotary knob to set the crest factor. (The crest factor is set to 2.0
in this example.)
0.00Ar 0.0Ap 95.1V
--CREST FACTOR 1.4--
RMS current value
Peak current value
RMS voltage value
Crest factor
0.00Ar 0.0Ap 95.1V
-- ISET 7.00A --
0.00Ar 0.0Ap 95.1V
--CREST FACTOR 1.4--
0.00Ar 0.0Ap 95.1V
--CREST FACTOR 2.0--
Summary of Contents for PCZ1000A
Page 4: ...ii PCZ1000A This page is intentionally blank ...
Page 17: ...General Description This chapter gives an overview and describes the features of the PCZ1000A ...
Page 35: ...Operation This chapter describes each mode and function of the operation ...
Page 82: ...5 4 PCZ1000A This page is intentionally blank ...
Page 83: ...Specifications This chapter gives the specifications and dimensions of the PCZ1000A ...
Page 88: ...6 6 PCZ1000A This page is intentionally blank ...
Page 89: ...The appendix contains the basic operating modes operating range and troubleshooting Appendix ...
Page 99: ......