background image

PCR-LE2 series

About the PCR-LE2 Documentation

These manuals are intended for users of the PCR-LE2 Series AC 
Power Supply and their instructors.
Explanations are given under the presumption that the reader has 
knowledge related to electric safety tests.
You can view the PDF file using Adobe Reader 6.0 or later.
The HTML can be viewed using the following browser.

Browser: Microsoft Internet Explorer 9.0 or later

Every effort has been made to ensure the accuracy of this manual. 
However, if you have any questions or find any errors or omissions, 
please contact your Kikusui agent or distributor.
If you find any misplaced or missing pages in this manual, it will be 
replaced. If the manual gets lost or soiled, a new copy can be pro-
vided for a fee. To replace or purchase a manual, please contact 
your Kikusui agent or distributor. At that time, inform your agent or 
distributor of the “Part No.” written on the front cover of this manual.
After you have finished reading this manual, store it so that you can 
use it for reference at any time.

Notations used in the PCR-LE2 manual

In the PCR-LE2 manual, the PCR-LE2 Series AC Power Supply is 
also referred to as the PCR-LE2 Series and the PCR-LE2.
The term “PC” is used to refer generally to both personal comput-
ers and workstations.
The screen captures used in this manual may differ from the actual 
screens that appear on the PCR-LE2. The screen captures are 
merely examples.
The following markings are used in the explanations in the manual.

WARNING

Indicates a potentially hazardous situation which, if ig-

nored, could result in death or serious injury.

CAUTION

Indicates a potentially hazardous situation which, if ignored, 

may result in damage to the product or other property.

- Note -
Indicates information that you should know.

- DESCRIPTION -
Explanation of terminology or operation principle.

(SHIFT+key name)

Indicates an operation that requires you to press a key indicated 
in blue characters (the lower row of text to the left of the key) 
while holding down the SHIFT key.

Contents of the Included CD-ROM

Put the included CD-ROM into the CD-ROM drive. In a few mo-
ments, a start window will appear. If the start window does not 
appear, open the CD-ROM folder in Windows Explorer, and then 
double-click index.html to display the start window.

Accompanying CD-ROM contains following the items.
•  KI-VISA x.x.x
•  IVI-COM
•  Operation Manual

Click the "See the Manual" to move to the Manual page.

- Tips -

How to view ePub files on a tablet

To view an ePub file on a tablet, an ePub reader (e.g., iBooks, Hi

-

mawari Reader) must be installed in the tablet. You can download 

ePub readers for free.

There are several ways to copy ePub files to your tablet, but we 

recommend that you download them from the Kikusui Electronics 

Corporation website.
1. Using a browser on your iPad, visit Kikusui Elec-

tronics Corporation website’s Operation Manual 

Database (http://www.kikusui.co.jp/en/down

-

load/), and search for your PCR-LE2 series.

2. Tap the appropriate ePub file to download it.
When an ePub file is downloaded to your tablet, you can view it 

even when the tablet is not connected to the Web.

Summary of Contents for PCR12000LE2

Page 1: ...and waveform can be changed over time Power supply environment testing can be automated In addition to the AC output sequences DC output single phase output or single phase three wire output only and...

Page 2: ...used in the explanations in the manual WARNING Indicates a potentially hazardous situation which if ig nored could result in death or serious injury CAUTION Indicates a potentially hazardous situatio...

Page 3: ...istance Using Power Line Abnormality Simulations In AC mode you can simulate power supply line errors by stop ping the PCR LE2 output and decreasing and increasing the voltage to simulate voltage dips...

Page 4: ...t least 20 cm of space between the air inlet outlet and the wall or obstacles Fix PCR6000LE2s and PCR9000LE2s to the floor using L shaped or other similar brackets Base Hold Angles OP03 KRC are availa...

Page 5: ...block tray in place Stopper 5 Connect the wires and cables to the terminal block and connectors as necessary 6 Return the stopper to its previous position 7 Return the terminal block tray to its prev...

Page 6: ...the switchboard attach crimping terminals that match the screws of the switchboard that has been connected by a qualified engi neer If you will not use one of the optional input power cords prepare a...

Page 7: ...ncy 50 Hz or 60 Hz 2 Check that the POWER switch is turned off 3 Unfasten the screws two locations of the AC INPUT terminal block cover and remove the cover 4 Connect the power cords according to the...

Page 8: ...rs are detected the home position the basic screen appears 0 00 A 0 0 V pk rms AC LOAD 99 00 Hz RANGE L RESP M OUTPUT OFF Turning on the POWER switch on the PCR12000LE2 PCR18000LE2 or 27000LE2 The PCR...

Page 9: ...ber 63 Output on off state If the POWER switch is turned off immediately after the settings have been changed the last settings may not be stored CAUTION Risk of malfunction After turning the POWER sw...

Page 10: ...uirements of single core wires that are used to connect to the load Nominal cross sectional area mm2 AWG reference cross sectional area mm2 Allowable current A at Ta 30 C 86 F 0 9 18 0 82 17 1 25 16 1...

Page 11: ...ill not flow through the PCR LE2 Series even if the POWER switch is turned on Single phase three wire output or three phase out put 1 Check that the POWER switch is turned off 2 Check that the breaker...

Page 12: ...0 mm2 AWG0 2 or less flip the terminal cover upside down and attach it Single phase output 1 Check that the POWER switch is turned off 2 Check that the breaker of the switchboard is off 3 Unfasten the...

Page 13: ...shock Before you install the switch between the OUTPUT ter minal block and the load be sure to turn the POWER switch off and turn off the breaker of the switchboard The current rating of the switch mu...

Page 14: ...s does exceed the limit defined in the SJ T11363 2006 standard The PCR LE2 series is subject to export control laws Trademarks All company names and product names used in the PCR LE2 manual are tradem...