GENERAL VISUAL AND AUDIBLE INDICATOR OPERATION

Red LED Indicator: 

The red LED will blink in conjunction with the alarm sound. 

Therefore, the red LED will blink during a smoke alarm, a low battery mode 
chirp, a unit error mode chirp or at end of unit life.

Fault Mode Indicator: 

These alarms monitor strategic functions of internal 

electronics and sensors. If a problem is detected the alarm will enter a fault 
mode. If this occurs the alarm will produce a single “chirp” approximately every 
30 seconds and blink the Red LED 2-12 times.  If this should occur call Kidde 
Customer service at 1-800-880-6788.

End of Unit Life Indicator: 

Ten years after initial power-up, this unit will 

“chirp” twice every 30 seconds to indicate that it is time to replace the alarm. 

This alarm has End of Life Hush

®

 which allows you to silence the trouble chirp for 

three days giving you extra time to replace the unit at a more convenient time. 

To activate, press the Test/Hush button. While in the End of Life Hush

®

 mode, 

the alarm will still detect Smoke. 

The End of Life signal can be reset a maximum of 10 times for a total of 30 
days. After 10 resets the end of life signal can no longer be silenced and the 
alarm must be replaced immediately.  

7. NUISANCE ALARMS

This Smoke alarm is designed to minimize nuisance alarms. Cigarette smoke will 
not normally cause the unit to alarm, unless the smoke is blown directly into the 
alarm. Combustion particles from cooking may set off the alarm if it is located 
too close to a cooking appliance. Large quantities of combustible particles are 
generated from spills or when broiling. Using the fan on a range hood which 
vents to the outside (non-recirculating type) will also help remove these combus-
tible products from the kitchen.

If the alarm does sound the smoke alarm pattern of 3 long beeps, check for fires 
first. If a fire is discovered, get out and call the fire department. If no fire is pres-
ent, check to see if one of the reasons listed in “Locations to avoid” may have 
caused the alarm. 

SMART HUSH

TM 

 CONTROL:

  The SMART HUSH

TM

 feature has the capability of 

temporarily desensitizing the alarm circuit for approximately 10 minutes. This 
feature is to be used only when a known alarm condition, such as smoke from 
cooking, activates the alarm. The smoke alarm is desensitized by pushing the 
Test/Hush button on the smoke alarm cover. If the smoke is not too dense, the 
alarm will silence immediately and the red LED blinks every 10 seconds. This 
indicates that the alarm is in a temporarily desensitized condition. 

Model P3010B

 will issue a voice prompt stating “Hush Mode Activated.” 

Model P3010H

 will turn off the amber safety light.

The smoke alarm will automatically reset after approximately 10 minutes and 
sound the alarm if particles of combustion are still present. 

Model P3010B

 will issue a voice prompt stating “Fire-Fire.”

The SMART HUSH

TM

 feature can be used repeatedly until the air has been 

cleared of the condition causing the alarm. Pushing the Test/Hush button on the 
alarm will end the temporarily desensitized period. 

Model P3010B

 will issue a voice prompt stating “Hush Mode Cancelled” after 

the Test/Hush button has been pressed.

If the smoke is not too dense, after ten minutes the alarm will return to normal 
operation.

Operational 

Mode

Visual  

Indications

Audible  

Indications

Note:

Normal Opera-

tion

Blink once every 60 

seconds

None

LED will flash every 60 seconds for 

10 minutes following power on or 

reset.  After initial 10 minutes,  

LED will flash once every  

10 minutes

Test/Hush But-

ton Press

Blink with each alarm 

pattern

Two sets of 3 long 

beeps

Test/Hush button press will initiate 

test sequence

Voice “Fire-Fire” 

announced

Model P3010B  

with Voice

Smoke Alarm 

Hush

Blink once every 10 

seconds

None (smoke alarm 

silenced)

Alarm hush feature silences smoke 

alarm for approx. 10 minutes. See 

page 13 for additional instructions.

Low Battery

Blink once every 30 

seconds

Chirp every 30 

seconds

Remove, turn off and  

replace alarm

Voice “Low Battery” 

announced

Model P3010B with Voice

Fault Mode

Fault code (2-12 

flashes every 30 

seconds)

Chirp every 30 

seconds

Remove, turn off and  

replace alarm

End of Unit 

Life*

2 blinks every 30 

seconds

2 chirps every 30 

seconds

Remove, turn off and  

replace alarm

End of Unit Life 

Hush

None

None (End of Life 

chirps silenced)

* End of life hush feature. Silences end of life indication 3 days at a time for  

a maximim of 30 days.

Summary of Contents for P3010B

Page 1: ...ntial environment It is not designed for use in a recreational vehicle RV or boat P N 0311 7201 RevA For your convenience write down the following information If you call Product Support these are the...

Page 2: ...ALARM ACTIVATION Smoke alarm pattern is three long beeps repeating Alert small children in the home as well as anyone else that might have difficulty recognizing the importance of the alarm sounding...

Page 3: ...otification to occupants of the need to escape followed by the appropriate egress actions by those occupants Fire warning systems for dwelling units are capable of protecting about half of the occupan...

Page 4: ...oid thermal barriers that may form at the ceiling For more details see MOBILE HOME INSTALLATION section When mounting an alarm on the ceiling locate it at a minimum of 4 10 cm from the side wall When...

Page 5: ...ks synchronized with audible alarm 3 long beeps repeating Model P3010L Smoke or Fire detected 3 blinks synchronized with audible alarm 3 long beeps repeating with voice Fire Fire announced Model P3010...

Page 6: ...esensitizing the alarm circuit for approximately 10 minutes This feature is to be used only when a known alarm condition such as smoke from cooking activates the alarm The smoke alarm is desensitized...

Page 7: ...nce the alarm is deactivated the battery will be depleted and the alarm will no longer function Once the alarm has been deactivated it cannot be mounted onto the mounting plate or reactivated WARNING...

Page 8: ...rop and Roll if clothes catch on fire and how to crawl low under smoke Install and maintain fire extinguishers on every level of the home and in the kitchen basement and garage NFPA NATIONAL FIRE PREV...

Page 9: ...allow the exclusion or limitation of incidental or consequential damages the above limitations or exclusions may not apply to you While this warranty gives you specific legal rights you may also have...

Reviews: