OPTION 2:  

Mounting on Other Surfaces

1. Choose a mounting location (wall or  

ceiling) and using the mounting plate  
provided as a template, mark three- 
hole locations.  

2. Install the three provided screws  

through the mounting plate and tighten.  
DO NOT over-tighten screws. (If  
mounting in plasterboard or similar  
surface, drill 3/16” holes and use the  
plastic anchors provided.) Anchors are  
not required for mounting on hard  
surfaces such as wood. 

ATTACHING AND ACTIVATING THE ALARM

This model is equipped with a feature that automatically activates the alarm 
when the alarm is attached to the mounting plate for the first time. Once acti-
vated, the battery will supply power to the alarm for the life of the alarm (10 
years) under normal conditions. 

Align the alarm with the mounting plate and rotate clockwise (right) approxi-
mately 45° until the unit stops and clicks into place. DO NOT over-tighten. If 
unit needs to be re-aligned, rotate the alarm counter clockwise, remove and 
rotate to desired alignment. NOTE: The alarm will mount to the plate in three  
(3) positions (every 120 degrees).

You will know power has been supplied when alarm briefly chirps. Unit will 
remain on until unit is disabled by the user at alarm’s end of life. Do not over 
tighten the alarm as damage to alarm or mounting surface may occur. 

The alarm is now activated! 

After installation/activation, test your alarm  

as described in Operation and Testing section.

 Warning: Failure to properly install and activate this alarm  

will prevent proper operation of this alarm and will prevent  
its response to fire hazards.

Model P3010B

 will issue a voice prompt at activation asking the user to press 

the test button. Proceed to Operation and testing section.

Alarm  

Mode

Visual  

Indications

Audible  

Indications

Note:

Smoke or Fire 

detected

3 blinks synchronized 

with audible alarm

3 long beeps, 

repeating

Model P3010L

Smoke or Fire 

detected

3 blinks synchronized 

with audible alarm

3 long beeps, 

repeating  with 

voice “Fire-Fire” 

announced

Model P3010B with Voice

Smoke or Fire 

detected

3 blinks synchronized 

with audible alarm & 

amber light illuminated

3 long beeps, 

repeating

Model P3010H with 

Emergency Safety Light

If you require further information please contact  

Product Support at 1-800-880-6788 or write us at: Kidde, 1016 Corporate 

Park Drive, Mebane, NC 27302. Our internet address is www.kidde.com.

5. OPERATION AND TESTING

OPERATION:

 The alarm is operating once it is activated and testing is complete. 

When products of combustion are sensed, the unit sounds a loud 85db pulsat-
ing alarm until the air is cleared.

TESTING

: Test your alarm by pressing the test button until the unit chirps, then 

release the test button. The unit will then emit 2 sets of three slow beeps. 

Model P3010B

 will also issue a voice prompt stating “Fire Fire”.

Model P3010H

 will briefly illuminate the amber safety light.

The alarm will sound if the electronic circuitry, horn, and battery are working.  
If the alarm does not sound, the unit must be replaced

 Warning: Due to the loudness (85 decibels) of the alarm, always 

stand an arm’s length (about 2.5 feet) away from the unit or use ear 
protection when testing.

Weekly testing is required to ensure proper operation

. Erratic or low 

volume sound (or no sound) coming from your alarm may indicate a defective 
alarm and it should be returned for service. See deactivation section to deter-
mine how to prepare the unit for shipment or disposal.

Warning: DO NOT use an open flame to test your alarm, you could dam-
age the alarm or ignite combustible materials and start a structure fire.

The following tables describes the visual and audible alarm conditions the unit 
may encounter and illustrates how the unit will indicate normal standby, alarm 
and error conditions.

6. Alarm Visual and Audible Indicators

Mounting 
Option 2

Summary of Contents for P3010B

Page 1: ...ntial environment It is not designed for use in a recreational vehicle RV or boat P N 0311 7201 RevA For your convenience write down the following information If you call Product Support these are the...

Page 2: ...ALARM ACTIVATION Smoke alarm pattern is three long beeps repeating Alert small children in the home as well as anyone else that might have difficulty recognizing the importance of the alarm sounding...

Page 3: ...otification to occupants of the need to escape followed by the appropriate egress actions by those occupants Fire warning systems for dwelling units are capable of protecting about half of the occupan...

Page 4: ...oid thermal barriers that may form at the ceiling For more details see MOBILE HOME INSTALLATION section When mounting an alarm on the ceiling locate it at a minimum of 4 10 cm from the side wall When...

Page 5: ...ks synchronized with audible alarm 3 long beeps repeating Model P3010L Smoke or Fire detected 3 blinks synchronized with audible alarm 3 long beeps repeating with voice Fire Fire announced Model P3010...

Page 6: ...esensitizing the alarm circuit for approximately 10 minutes This feature is to be used only when a known alarm condition such as smoke from cooking activates the alarm The smoke alarm is desensitized...

Page 7: ...nce the alarm is deactivated the battery will be depleted and the alarm will no longer function Once the alarm has been deactivated it cannot be mounted onto the mounting plate or reactivated WARNING...

Page 8: ...rop and Roll if clothes catch on fire and how to crawl low under smoke Install and maintain fire extinguishers on every level of the home and in the kitchen basement and garage NFPA NATIONAL FIRE PREV...

Page 9: ...allow the exclusion or limitation of incidental or consequential damages the above limitations or exclusions may not apply to you While this warranty gives you specific legal rights you may also have...

Reviews: