background image

FIGURE 8

FIGURE 7

Location of Posts:

2. After selecting the proper smoke alarm location as described in Section 1, attach

the mounting bracket to the ceiling as shown in Figure 3. For wall mounting see
Figure 4.  Place the mounting plate on the wall; be sure the “A” line is horizontal
(parallel to the floor). Use the screws and cavity fixings provided to secure the
mounting bracket (use 3/16” drill bit for cavity fixings.).

3. This alarm has a battery permanently sealed inside the alarm no battery installation

or maintenance is necessary.

Note: Ex tensiv e cy cling betw een high and low  temperatures w ill significantly

reduce battery  life.  Long term ex posure to high temperatures w ill degrade
the battery  ov er time.  Kidde recommends locating this alarm in a con-
trolled temperature env ironment (20-30ºC) for optimum life.

ACTIVATING THE ALARM

Once activ ated, the battery  w ill supply  pow er to the alarm for the life of the
alarm (10 y ears).  Be sure that the mounting bracket is mounted correctly
before installing the alarm on the mounting bracket.

1. To activate the alarm, install the alarm on the mounting bracket (Figure 6) and

rotate the alarm clockwise (as indicated on the alarm cover) until the alarm snaps
into place .

The alarm is now activated!

2. After installation/activation, test your alarm by depressing and holding down the

test button for a minimum of 1 second (or until the alarm sounds).  This should
sound the alarm. The alarm will sound at a low level to avoid discomfort. If the test
button is pressed for greater than 5 seconds, the alarm will sound at the full 85
decibels and may cause some discomfort 

TAMPER RESIST FEATURE

Smoke Alarm Tamper Resist Feature

This alarm is equipped with a tamper resist feature that helps prevent someone from
removing the unit from the mounting bracket.  When activated, it can be very effec-
tive in preventing smoke alarm removal or tampering.

Activate the smoke alarm tamper resist feature by breaking out the small tab in the
square hole in the mounting bracket (see Figure 7).  When the tab is broken off, the
tamper resist on the base is allowed to engage the mounting bracket.  Rotate the
alarm onto the mounting bracket until you hear the tamper resist tab snap into place,
locking the alarm on the mounting bracket.  Using the tamper resist feature will help
deter children and others from removing the alarm from the bracket.  NOTE: To
remove the alarm when the tamper resist tab is engaged, press down on the tamper
resist tab and rotate the alarm in the direction indicated by the arrows on the cover of
the alarm (see Figure 8).

0308-7201-02(21008570B)_En.qxd:_  2012.2.16  12:10 PM  Page

Summary of Contents for 10Y29

Page 1: ...product to provide the highest quality safety protection We know you expect nothing less when the lives of your family are at stake 10Y29 Smoke Alarm User s Guide For model 10Y29 Smoke Alarm Model Num...

Page 2: ...in the immediate area of the bedrooms Try to monitor the exit path as the bedrooms are usually farthest from the exit If more than one sleeping area exists locate additional alarms in each sleeping ar...

Page 3: ...alarms in rooms with ceil ing slopes greater than 3 m in 2 4 m 1 foot in 8 feet horizontally shall be located on the high side of the room A row of detectors shall be spaced and located within 0 9 m 3...

Page 4: ...forced air supply ducts used for heating or cooling ceiling or whole house ventilating fans or other high air flow areas Kitchens Normal cooking may cause nuisance alarms Near fluorescent lights inclu...

Page 5: ...alarm is now activated 2 After installation activation test your alarm by depressing and holding down the test button for a minimum of 1 second or until the alarm sounds This should sound the alarm T...

Page 6: ...The LED will flash every 0 5 seconds when the alarm is sounding The flashing LED and pulsating alarm will continue until the air is cleared The LED will flash every 10 seconds while in Hush mode The...

Page 7: ...nt is necessary for the life of the alarm WARNING DO NOT ATTEMPT TO OPEN THE ALARM FOR ANY REASON To activate the alarm attach the alarm to the mounting bracket by rotating in the direction of the arr...

Page 8: ...hey cannot escape even when warned early enough that escape should be possible For these people other strategies such as protection in place or assisted escape or rescue are necessary Smoke alarms are...

Page 9: ...rder to execute the escape plan Practice allows all occupants to test your plan before an emergency You may not be able to reach your children It is important they know what to do WHAT TO DO WHEN THE...

Page 10: ...is recommended that the householder consider the use of additional smoke alarms for those areas for increased protection The additional areas include the basement bedrooms dining room utility room an...

Page 11: ...ge and return postage prepaid to Warranty Service Department Kidde Safety Europe Mathisen Way Colnbrook Slough Berkshire SL3 OHB This warranty shall not apply to the smoke alarm if it has been damaged...

Reviews: