4.OPERATION AND TESTING

OPERATION: The smoke alarm is operating once the alarm is activated (see Section 3)
and testing is complete.  When products of combustion are sensed, the unit sounds a
loud 85db pulsating alarm until the air is cleared.  If there is any question as to the
cause of the alarm, it should be assumed that the alarm is due to an actual fire and
the dwelling should be evacuated immediately.

HUSH

TM

CONTROL: NOTE:  Hush control and test button are a single button. The

HUSH

TM

feature has the capability of temporarily desensitising the alarm circuit for

approximately 10 minutes.  This feature is to be used only when a known alarm con-
dition, such as smoke from cooking, activates the alarm. The smoke alarm is desensi-
tised by pushing the HUSH

®

button on the smoke alarm cover. The alarm will silence

immediately, and the LED will flash every 10 seconds to signal that the alarm is in
Hush mode.  The smoke alarm will automatically reset after approximately 10 minutes.
The HUSH

TM

feature can be used repeatedly until the air has been cleared of the

condition causing the alarm. Pushing the test/reset button on the alarm will end the
temporarily desensitised period.

NOTE: DENSE SMOKE WILL OVERRIDE THE HUSH

TM

CONTROL FEATURE.

CAUTION: BEFORE USING THE ALARM HUSH

TM

FEATURE, IDENTIFY THE

SOURCE OF THE SMOKE AND BE CERTAIN A SAFE CONDITION EXISTS.

FLASHING LED LIGHT: This smoke alarm is equipped with a flashing red indicator light
with the following modes of operation:

• The LED will flash every every 60-70 seconds in the standby mode signifying that

the alarm is receiving power.

• The LED will flash every 0.5 seconds when the alarm is sounding. The flashing LED

and pulsating alarm will continue until the air is cleared.

• The LED will flash every 10 seconds while in Hush mode.

• The LED will flash twice every 30 seconds when the alarm is within 30 days of end

of life.

• The LED will flash every 30 seconds (with a chirp every 60 seconds) when the alarm

is at end of life.  (replace alarm immediately)

• The alarm will chirp every 30 seconds without an LED flash to indicate a fault

condition with the processor of the alarm.

TESTING: Test by pushing the test/Hush button on the cover and holding it down for a
minimum of 1 second (or until the alarm sounds).  Note:  the first test sequence will
be at a lower volume.  Holding the test/Hush button for longer than 5 seconds will
result in the full 85 decibel sound output. This will sound the alarm if the electronic
circuitry, horn, and battery  are working.  If no alarm sounds, the unit has a defective
battery or other failure. DO NOT use an open flame to test your alarm, you could
damage the alarm or ignite combustible materials and start a structure fire.

SMOKE SENSING CHAMBER OPERATION: This alarm will "chirp" every 30 seconds
(with red LED flash at the same time) if it detects a problem with the smoke sensing
chamber. 

NOTE: WEEKLY TESTING IS REQUIRED.

TEST THE ALARM WEEKLY TO ENSURE PROPER OPERATION. Erratic or low sound
coming from your alarm may indicate a defective alarm, and it should be returned for
service.

If your alarm regularly 

nuisance alarms

(See Section 5) when cooking,

this indicates the alarm may be mounted too close to the source e.g..

kitchen. However, by pressing the 

Hush

button prior to cooking, you can

densisitise the alarm for approximately 10 minutes.

0308-7201-02(21008570B)_En.qxd:_  2012.2.16  12:10 PM  Page

Summary of Contents for 10Y29

Page 1: ...product to provide the highest quality safety protection We know you expect nothing less when the lives of your family are at stake 10Y29 Smoke Alarm User s Guide For model 10Y29 Smoke Alarm Model Num...

Page 2: ...in the immediate area of the bedrooms Try to monitor the exit path as the bedrooms are usually farthest from the exit If more than one sleeping area exists locate additional alarms in each sleeping ar...

Page 3: ...alarms in rooms with ceil ing slopes greater than 3 m in 2 4 m 1 foot in 8 feet horizontally shall be located on the high side of the room A row of detectors shall be spaced and located within 0 9 m 3...

Page 4: ...forced air supply ducts used for heating or cooling ceiling or whole house ventilating fans or other high air flow areas Kitchens Normal cooking may cause nuisance alarms Near fluorescent lights inclu...

Page 5: ...alarm is now activated 2 After installation activation test your alarm by depressing and holding down the test button for a minimum of 1 second or until the alarm sounds This should sound the alarm T...

Page 6: ...The LED will flash every 0 5 seconds when the alarm is sounding The flashing LED and pulsating alarm will continue until the air is cleared The LED will flash every 10 seconds while in Hush mode The...

Page 7: ...nt is necessary for the life of the alarm WARNING DO NOT ATTEMPT TO OPEN THE ALARM FOR ANY REASON To activate the alarm attach the alarm to the mounting bracket by rotating in the direction of the arr...

Page 8: ...hey cannot escape even when warned early enough that escape should be possible For these people other strategies such as protection in place or assisted escape or rescue are necessary Smoke alarms are...

Page 9: ...rder to execute the escape plan Practice allows all occupants to test your plan before an emergency You may not be able to reach your children It is important they know what to do WHAT TO DO WHEN THE...

Page 10: ...is recommended that the householder consider the use of additional smoke alarms for those areas for increased protection The additional areas include the basement bedrooms dining room utility room an...

Page 11: ...ge and return postage prepaid to Warranty Service Department Kidde Safety Europe Mathisen Way Colnbrook Slough Berkshire SL3 OHB This warranty shall not apply to the smoke alarm if it has been damaged...

Reviews: