SMOKE SENSOR 

 

Introduction 

Smoke Sensor is a universal, Z-Wave compatible sensor. The device can be hard wire (12 or 

24V DC) or battery operated (battery life 3 years). Smoke detection is signaled through siren and 

LED  diode  blinking.  Additionally,  the  smoke  sensor  signal  can  be  sent  to  alarm  system  or  fire 

alarm system hub, through a NC (normally closed) contact terminal. 

The  optical  sensor  detects  smoke  at  an  early  stage  of  fire,  often  before  flames  appear  and 

temperature  starts  to  rise  significantly.  Moreover  the  device  has  a  built-in  temperature  sensor, 

which can also trigger the alarm once the specified temperature threshold is exceeded. 

Smoke Sensor is designed to be placed on a wall or ceiling. LED indicator signals fire, oper-

ating mode and used to see if device is within the Z-Wave network. 

Technical Information 

 

Compatible with any Z-Wave network controller 

CT-SMZW2007-FBR 

Smoke Sensor 

 

Summary of Contents for CT-SMZW2007-FBR

Page 1: ...gh a NC normally closed contact terminal The optical sensor detects smoke at an early stage of fire often before flames appear and temperature starts to rise significantly Moreover the device has a built in temperature sensor which can also trigger the alarm once the specified temperature threshold is exceeded Smoke Sensor is designed to be placed on a wall or ceiling LED indicator signals fire op...

Page 2: ...t terminals maximum current carrying capacity 25mA Maximum voltage at output terminal 24V AC DC Operational Temperature 0 40 Measured Temperature 20 100 Range up to 50m outdoors up to 30m indoors depending on the building materials used Dimension 65mm x 28mm Installation Instructions It s recommended to install the sensor on the ceiling or upper portion of wall at least 40cm from corners and other...

Page 3: ...is hard wired to power source drill holes in sensor s cover Note the sensor may be connected to a wired alarm system controller or fire prevention system 3 Install the cover in desired location 4 If the sensor is to be VDC powered connect wires observing Fig 1 If the sensor is to be connected to alarm system connect wires observing Fig 2 5 Screw the smoke sensor into the cover 6 Include the module...

Page 4: ...ci fied wake up intervals or at a manual wake up triple click B button In DC powering mode con figuration and association parameters are sent when necessary and additionally the smoke sensor serves as a Z Wave signal repeater Switching to a constant current powering mode 1 Exclude a sensor from the Z Wave network 2 Disconnect the battery 3 Install the constant power connecting terminal observing t...

Page 5: ... 5 seconds 4 Please go to the device list interface and refresh the device list the device will not be dis played 5 If the device can still be displayed network exclusion failed repeat steps 2 4 NOTE If the device is online directly perform steps 1 5 if the device is offline need interruption of the device power supply first and then perform step 1 5 DEVICE RESET Reset procedure clears the modules...

Page 6: ... with the understanding of wiring diagrams and knowledge of electrical safety should complete installation following the instructions Before installation please confirm the real voltage complying with the device s specification Cut off any power supply to secure the safety of people and device During installation protect the device from any physical damage by dropping or bumping If happened please...

Reviews: