Setting the KICstart Maximum Temperature
The
Maximum Temperature
setting for the
KICstart
refers to the highest temperature that the
KICstart
is
set to read. When you received your
KICstart
, it was preset for 932°F (500°C) as it's M
aximum
Temperature
. It can be changed. The highest temperature that the
KICstart
is capable of reading is
1050
°
C.
TIP: If you exceed this temperature while running a profile, your TC inputs will read OVR (over-
range). If this happens to you, the first thing to suspect is that the Maximum Temperature setting
for your KICstart is not set high enough for the temperature application you're attempting to
measure.
See instructions above for enabling the KIC Host screen.
Follow these steps to change the KICstart Maximum Temperature.
•
Turn on the computer and start the
KICstart
software.
•
Connect your
KICstart
to the computer via the communication cable.
•
Turn on your
KICstart
.
•
Observe the
Host
screen. The number that you'll be calibrating is the
Max. Temp. Capability
.
•
Remove the cover of the
KICstart
, using a small screwdriver adjust the Max. Temp. Potentiometer
very slowly until the desired maximum temperature is achieved. This poteniometer is very
sensitive.
o
Turn Clockwise to decrease the
Maximum Temperature
.
o
Turn Counterclockwise to increase the
Maximum Temperature.