Once you have selected your thermocouples, you are ready to profile.
Make sure the
KICstart
profiler hardware is properly connected to the computer. You will be able to view
the live readings for each selected thermocouple. If you don’t see the live readings, the
KICstart
hardware
is not connected properly. Recheck the cable connections, and make sure a fresh battery is installed.
Select the
Start Profile
(Green traffic light) button to begin profiling.
The
KICstart
software requires that the selected thermocouples read valid temperatures below the
Maximum product temperature at start of profile
as displayed in the
Global Preferences
screen. The
default setting is 40ºC/104ºF.
If any of the selected thermocouples read too high, this message will appear:
When the
KICstart
software detects valid temperatures for all of the selected thermocouples, it will allow
you to start the profile.
In certain situations the KICstart software may display other messages with directions in addition to
what is outlined below. Read these messages and follow these directions carefully.
Next, the
KICstart
software will ask you to
verify the oven is stable.
•
Yes –
The software will prompt you
to put the
KICstart
and the board in
to the oven.
•
No –
The software will return you to
the main screen to start again.
•
The software will ask you to change the oven
setpoint temperatures to the temperatures that
the control thermocouples are currently
reading and then start the profile again, press
OK.