![KIC start User Manual Download Page 43](http://html1.mh-extra.com/html/kic/start/start_user-manual_1963758043.webp)
Version 1.1.0.x
KICstart
36
KICstart User Manual
Temperature Triggers
The default
KICstart
temperature triggers are as follows:
Wave Solder-Wave
ON
Wave Solder-Wave
OFF
Profile start
33ºC/92ºF
Profile start
33ºC/92ºF
Mid trigger
110ºC/230ºF Mid trigger
130C/266F
Profile end
90ºC/194ºF Profile end
110C/230F
The default trigger values should be fine for most processes. The
Profile Start
-trigger is determined by the
Maximum product temperature at start of profile
setting in the
Global Preferences
screen. The start trigger
value is always 2ºC above this setting. In the event that the mid-trigger, or end trigger values need to be
changed, contact KIC Technical support,
KICstart Profile Download
While the KIC
start
profiler is profiling, it stores the profile data in its on board memory. Once the
KIC
start
detects that all of the thermocouples have cooled below the profile-end trigger value, it will begin
downloading the profile data. Connect the
KICstart
communication cable to the
KICstart
and the
download will begin automatically.
The KICstart profiler will be hot to the touch. Use gloves if necessary to avoid burn injuries while
connecting the communication cable.
When downloading begins, the
KICstart
will send the profile in data packets. The downloading status is
displayed at the bottom of the profile screen.
When all of the data packets have been received, the software will display a message asking you to turn the
KICstart
off, choose OK. Failing to turn the
KICstart
off will drain the battery.
Next, the
KICstart
software will present the profile and
Statistics
.
If the
Air TC
or either
Wave TC
does not touch the wave(s), the
KICstart
software will display an error
message: