Lancaster

®

 Auditorium Seating with Power & Data

Assembly Instructions

Assemble units as described herein only. To do otherwise 
may result in instability. All screws, nuts and bolts must be  
tightened securely and must be checked periodically after  
assembly. Failure to assemble properly, or to secure parts 
may result in assembly failure and personal injury.

Power & Data Distribution 

Note:

 Figure 10 illustrates a

three-place unit with power 

infeed and typical power 

connections, as well as separate 

data infeed and routing. When 

power is to continue on, as with 

four or more seats, a simplex 

module end and another power 

distribution harness will plug 

into the housing end of the first 

distribution harness.

Note:

 Data wires and data jacks

are to be furnished by customer.

1. At the data infeed location, route

the data wires up through the data

infeed cover and along the seat 

backs. Leave enough slack in the

wires to allow for installation of

the wireway covers (Figure 10).

2. Fasten the data bracket to the

simplex receptacle using two

#8 x 

3

8

” Torx head wood screws.

A variety of data jacks can be

accommodated using the pack of

multiple data adapters 

(Figure 10).

3. Make the appropriate data wire

connections and snap into the

data adapter (Figure 10).

4. If no electrical distribution is 

necessary, see Figure 10 for 

wireway cover installation. 

Otherwise, continue on to the 

next steps. 

Note:

 Follow the space-planning

layout provided (also reference

power infeed examples) to stage

electrical components as

specified. The simplex receptacle

in each powered upright will have

a length of flexible conduit with  

connector end on it. At power 

infeed location(s), a power infeed 

cover assembly is used to bring 

power in. 46”, 49”, and 52” 

power distribution harnesses 

run to every other seat, passing 

power to each individual seating 

location. A 25” power distribution 

harness is used with a mid-row 

power infeed, and at the end of 

a row with an odd number of 

seating locations.

5. Check to be certain that each

upright is installed with the

correct electrical circuit

designation, as specified in the

space-planning layout.

6. At the power infeed location,

connect the two simplex module 

connector ends into the quad 

block #1 at the power infeed 

harness (Figure 10). Do not 

connect the 5-wire end of

the power infeed harness to a

power source at this time.

7. Plug the connector end of the

distribution harness into the

remaining location in the housing

end of the power infeed harness.

Route the housing end of the 

power distribution harness 

between the next two sets of leg 

uprights and connect the simplex 

end plug into it as illustrated. 

8. Hold the joined electrical

components up against the inside

center of the back panel to 

prepare for installation of wireway 

covers next page.

Summary of Contents for Lancaster Auditorium Seating

Page 1: ...Assembly Instructions Lancaster Auditorium Seating with Power Data December 2020...

Page 2: ...ttachment 5 Power Data Module and Power Infeed Installation 6 Data Infeed Installation 7 Power Data Distribution 8 Power Data Wireway Cover Installation 9 Power Data Side Cover Installation 10 End Pan...

Page 3: ...Stage product for installation 6 Locate and mark layout reference points 7 Locate and drill upright holes into floor 8 Attach uprights to the floor following the space planning layout Install anchor b...

Page 4: ...be measured from front bracket to front bracket Rear slot center to center dimension must remain at 20 22 233 8 or 24 for straight runs and radius installations For a radius of 40 or less 1 8 is added...

Page 5: ...units as described herein only To do otherwise may result in instability All screws nuts and bolts must be tightened securely and must be checked periodically after assembly Failure to assemble prope...

Page 6: ...Note If any lighted end panel uprights are to be installed see appropriate pages 11 or 14 and install wiring before installing upright s to the floor 1 Align the holes in the upright foot with the flo...

Page 7: ...Rotate the back assembly until the appropriate hole in the back bracket lines up with the upper rear hole in the upright Place a 1 4 20 x 5 8 Torx head screw in the hole in the top of the back bracket...

Page 8: ...power infeed bottom bracket below using 1 4 20 x 5 8 Torx head screws and 1 4 20 acorn nuts Figure 8 3 Position the power data infeed end cover as illustrated up to the installed power infeed outer b...

Page 9: ...upright using the floor fastener bolt which secures the upright to the floor Figure 9 2 Attach the power data infeed outer box to the upright arm gusset at the top and to the power data infeed bottom...

Page 10: ...is necessary see Figure 10 for wireway cover installation Otherwise continue on to the next steps Note Follow the space planning layout provided also reference power infeed examples to stage electrica...

Page 11: ...ly or to secure parts may result in assembly failure and personal injury 9 Power Data Wireway Cover Installation Note Refer to space planning layout for size locations at seats 1 Install the lower wir...

Page 12: ...power data side cover between the back upholstery and the back bracket Figure 12 2 Rotate the side cover until the two square holes snap over the receptacle and data adapter installed to the upright...

Page 13: ...20 x 11 4 top screws Aisle Lights Note The LED aisle light wiring is to be connected to a 12VDC Class II power supply by a qualified electrician who must check the electrical integrity of the finished...

Page 14: ...th a 3 8 16 locking nut under the upright seat support Do not secure the other side as the next seat will sit on the previous seat s seat tab Note The first and every other seat odd seats rest on the...

Page 15: ...or back attachment and seat attachment as described previously Figures 3 4 5 and 15 If equipped with accessories like tablet arms or end panels refer to those sections of the assembly instructions 4 P...

Page 16: ...o the ADA end panel At the top also one 1 4 20 x 5 8 will go through the same end panel ADA bracket and thread into the end panel Figure 19 2 Next orient the end panel bottom bracket as illustrated an...

Page 17: ...assembly Failure to assemble properly or to secure parts may result in assembly failure and personal injury 15 Hardware Overview All hardware illustrated at left is shown actual size 1 20 x 1 torx he...

Page 18: ...riodically after assembly Failure to assemble properly or to secure parts may result in assembly failure and personal injury 5 Wire Installation Power Infeed to Building Connections Have a certified e...

Page 19: ...Lancaster Auditorium Seating with Power Data Assembly Instructions 17...

Page 20: ...Street P O Box 8100 Green Bay Wisconsin 54308 8100 1 800 424 2432 www ki com KI is a registered trademark of Krueger International Inc 2020 Krueger International Inc All Rights Reserved Code KI 61620...

Reviews: