background image

Lancaster

®  

Auditorium Seating with Power & Data

Assembly Instructions

Assemble units as described herein only. To do otherwise 
may result in instability. All screws, nuts and bolts must be  
tightened securely and must be checked periodically after  
assembly. Failure to assemble properly, or to secure parts 
may result in assembly failure and personal injury.

3

Summary of Contents for Lancaster Auditorium Seating

Page 1: ...Assembly Instructions Lancaster Auditorium Seating with Power Data December 2020...

Page 2: ...ttachment 5 Power Data Module and Power Infeed Installation 6 Data Infeed Installation 7 Power Data Distribution 8 Power Data Wireway Cover Installation 9 Power Data Side Cover Installation 10 End Pan...

Page 3: ...Stage product for installation 6 Locate and mark layout reference points 7 Locate and drill upright holes into floor 8 Attach uprights to the floor following the space planning layout Install anchor b...

Page 4: ...be measured from front bracket to front bracket Rear slot center to center dimension must remain at 20 22 233 8 or 24 for straight runs and radius installations For a radius of 40 or less 1 8 is added...

Page 5: ...units as described herein only To do otherwise may result in instability All screws nuts and bolts must be tightened securely and must be checked periodically after assembly Failure to assemble prope...

Page 6: ...Note If any lighted end panel uprights are to be installed see appropriate pages 11 or 14 and install wiring before installing upright s to the floor 1 Align the holes in the upright foot with the flo...

Page 7: ...Rotate the back assembly until the appropriate hole in the back bracket lines up with the upper rear hole in the upright Place a 1 4 20 x 5 8 Torx head screw in the hole in the top of the back bracket...

Page 8: ...power infeed bottom bracket below using 1 4 20 x 5 8 Torx head screws and 1 4 20 acorn nuts Figure 8 3 Position the power data infeed end cover as illustrated up to the installed power infeed outer b...

Page 9: ...upright using the floor fastener bolt which secures the upright to the floor Figure 9 2 Attach the power data infeed outer box to the upright arm gusset at the top and to the power data infeed bottom...

Page 10: ...is necessary see Figure 10 for wireway cover installation Otherwise continue on to the next steps Note Follow the space planning layout provided also reference power infeed examples to stage electrica...

Page 11: ...ly or to secure parts may result in assembly failure and personal injury 9 Power Data Wireway Cover Installation Note Refer to space planning layout for size locations at seats 1 Install the lower wir...

Page 12: ...power data side cover between the back upholstery and the back bracket Figure 12 2 Rotate the side cover until the two square holes snap over the receptacle and data adapter installed to the upright...

Page 13: ...20 x 11 4 top screws Aisle Lights Note The LED aisle light wiring is to be connected to a 12VDC Class II power supply by a qualified electrician who must check the electrical integrity of the finished...

Page 14: ...th a 3 8 16 locking nut under the upright seat support Do not secure the other side as the next seat will sit on the previous seat s seat tab Note The first and every other seat odd seats rest on the...

Page 15: ...or back attachment and seat attachment as described previously Figures 3 4 5 and 15 If equipped with accessories like tablet arms or end panels refer to those sections of the assembly instructions 4 P...

Page 16: ...o the ADA end panel At the top also one 1 4 20 x 5 8 will go through the same end panel ADA bracket and thread into the end panel Figure 19 2 Next orient the end panel bottom bracket as illustrated an...

Page 17: ...assembly Failure to assemble properly or to secure parts may result in assembly failure and personal injury 15 Hardware Overview All hardware illustrated at left is shown actual size 1 20 x 1 torx he...

Page 18: ...riodically after assembly Failure to assemble properly or to secure parts may result in assembly failure and personal injury 5 Wire Installation Power Infeed to Building Connections Have a certified e...

Page 19: ...Lancaster Auditorium Seating with Power Data Assembly Instructions 17...

Page 20: ...Street P O Box 8100 Green Bay Wisconsin 54308 8100 1 800 424 2432 www ki com KI is a registered trademark of Krueger International Inc 2020 Krueger International Inc All Rights Reserved Code KI 61620...

Reviews: