background image

Lancaster

®  

Auditorium Seating with Power & Data

Assembly Instructions

Assemble units as described herein only. To do otherwise 
may result in instability. All screws, nuts and bolts must be  
tightened securely and must be checked periodically after  
assembly. Failure to assemble properly, or to secure parts 
may result in assembly failure and personal injury.

1

11.  Attach power & data modules,

electrical components, data 

wires and data jacks (optional).

Note:

 If unit is powered, the end

panel is installed at the same time

as the above items.

12.  Attach and route the power 

& data infeed connections 

(optional).

13.  Attach side covers (required with

power & data or optional without 

power & data).

14.  Attach end panel (required with

power & data or optional without 

power & data).

15.  Install the seats.

16.  Tighten floor anchors.

17.  Install ADA removable bases

(optional).

Note:

 ADA bases are not

available with power & data.

18.  Mount row and seat numbering

(optional).

19.  Clean product and site.

20.  Walk through with installation

crew to assure the product has

been installed per Lancaster

Auditorium Seating Assembly

Instructions and space-planning

layout.

21.  Perform final walk through with

the customer. Receive sign-off.

Note:

 Dimensional spacing

referenced is centerline to

centerline unless otherwise noted.

Concrete Floors

• 

5

16

 -18 or 

3

8

 -16 grade 5 

expansion anchors

•  Standard flat washers, plated

•  LockTite (red) thread lock or 

equal

•  Two screw assemblies 

required per upright

Note:

 Floor-mounting fasteners are

not provided.

Steps For Installation

1.    Read and review Lancaster

Auditorium Seating Assembly

Instructions.

2.    Review space-planning layouts.

3.    Review job site and verify

field conditions.

4.    Verify floor structural 

conditions.

5.    Stage product for installation.

6.    Locate and mark layout

reference points.

7.    Locate and drill upright holes

into floor.

8.    Attach uprights to the floor,

following the space-planning

layout. Install anchor bolts (not

provided) loosely to allow for

adjustment.

9.    Attach backs to the uprights. 

Refer to the space-planning 

layout to determine location of 

sizes and which top hole should 

be used on the back bracket 

(to determine the back angle) 

(center hole is standard).

Note:

 Optional power & data

components should be installed

before the seats are assembled.

10.  Install aisle light tube and 

housing (optional).

Note:

 Read these assembly

instructions carefully prior to 

product installation. Electrically

interconnected furnishings 

must also be mechanically 

interconnected. Product failure 

and personal injury may result if 

instructions are not followed.

Minimum Construction

Required For Upright

Installation

Wood Floors

•  Minimum two layers of 

3

4

” 

thick plywood

•  APA rated grade plywood

•  Allow minimum embedment 

1

1

2

” with lag screws

•  Use toggle bolt if less than 

1

1

2

” embedment

Concrete Floors

•  3000 psi concrete 

compressive strength

•  3” thick free of obstructions 

for 1

1

2

•  4” thick for riser mount free of 

obstruction for 2

1

2

•  Riser to be plumb within 

1

8

°

•  Minimum anchor embedment 

1

1

2

Note:

 Warranty null and void if KI 

Lancaster Seating product line is 

installed on flooring not meeting 

minimum structural requirements 

stated above.

Floor Fastener Requirements

Wood Floors

 5

16

” x 1

3

4

” lag bolts 

•  Grade 5

• 

5

16

” flat washers

• 

3

8

” toggle bolts

•  All hardware to be plated

•  Two bolt assemblies required 

per upright

Tools Required:

•  Hammer drill and bit for concrete 

anchor holes

•  Drill and bit for pilot holes in 

wood floors

•  Torx 27 head for back screws and 

end panels

•  Torx 20 head for electrical covers

• 

9

16

” deep well socket with ratchet

• 

7

16

” open-faced wrench

• 

9

16

” open-faced wrench

•  Chalk line

•  Tape measure

•  Torque wrench

Summary of Contents for Lancaster Auditorium Seating

Page 1: ...Assembly Instructions Lancaster Auditorium Seating with Power Data December 2020...

Page 2: ...ttachment 5 Power Data Module and Power Infeed Installation 6 Data Infeed Installation 7 Power Data Distribution 8 Power Data Wireway Cover Installation 9 Power Data Side Cover Installation 10 End Pan...

Page 3: ...Stage product for installation 6 Locate and mark layout reference points 7 Locate and drill upright holes into floor 8 Attach uprights to the floor following the space planning layout Install anchor b...

Page 4: ...be measured from front bracket to front bracket Rear slot center to center dimension must remain at 20 22 233 8 or 24 for straight runs and radius installations For a radius of 40 or less 1 8 is added...

Page 5: ...units as described herein only To do otherwise may result in instability All screws nuts and bolts must be tightened securely and must be checked periodically after assembly Failure to assemble prope...

Page 6: ...Note If any lighted end panel uprights are to be installed see appropriate pages 11 or 14 and install wiring before installing upright s to the floor 1 Align the holes in the upright foot with the flo...

Page 7: ...Rotate the back assembly until the appropriate hole in the back bracket lines up with the upper rear hole in the upright Place a 1 4 20 x 5 8 Torx head screw in the hole in the top of the back bracket...

Page 8: ...power infeed bottom bracket below using 1 4 20 x 5 8 Torx head screws and 1 4 20 acorn nuts Figure 8 3 Position the power data infeed end cover as illustrated up to the installed power infeed outer b...

Page 9: ...upright using the floor fastener bolt which secures the upright to the floor Figure 9 2 Attach the power data infeed outer box to the upright arm gusset at the top and to the power data infeed bottom...

Page 10: ...is necessary see Figure 10 for wireway cover installation Otherwise continue on to the next steps Note Follow the space planning layout provided also reference power infeed examples to stage electrica...

Page 11: ...ly or to secure parts may result in assembly failure and personal injury 9 Power Data Wireway Cover Installation Note Refer to space planning layout for size locations at seats 1 Install the lower wir...

Page 12: ...power data side cover between the back upholstery and the back bracket Figure 12 2 Rotate the side cover until the two square holes snap over the receptacle and data adapter installed to the upright...

Page 13: ...20 x 11 4 top screws Aisle Lights Note The LED aisle light wiring is to be connected to a 12VDC Class II power supply by a qualified electrician who must check the electrical integrity of the finished...

Page 14: ...th a 3 8 16 locking nut under the upright seat support Do not secure the other side as the next seat will sit on the previous seat s seat tab Note The first and every other seat odd seats rest on the...

Page 15: ...or back attachment and seat attachment as described previously Figures 3 4 5 and 15 If equipped with accessories like tablet arms or end panels refer to those sections of the assembly instructions 4 P...

Page 16: ...o the ADA end panel At the top also one 1 4 20 x 5 8 will go through the same end panel ADA bracket and thread into the end panel Figure 19 2 Next orient the end panel bottom bracket as illustrated an...

Page 17: ...assembly Failure to assemble properly or to secure parts may result in assembly failure and personal injury 15 Hardware Overview All hardware illustrated at left is shown actual size 1 20 x 1 torx he...

Page 18: ...riodically after assembly Failure to assemble properly or to secure parts may result in assembly failure and personal injury 5 Wire Installation Power Infeed to Building Connections Have a certified e...

Page 19: ...Lancaster Auditorium Seating with Power Data Assembly Instructions 17...

Page 20: ...Street P O Box 8100 Green Bay Wisconsin 54308 8100 1 800 424 2432 www ki com KI is a registered trademark of Krueger International Inc 2020 Krueger International Inc All Rights Reserved Code KI 61620...

Reviews: