Filter/Motor Indicator LED (ML/FL) - PSC Units
Sample line string: Krown-X-X//
I/SUPPLY/24/48//RSR/HEPA/FC/
PSC
/115//R+TMB/
FL+ML
/PSC-WK/TC/DSW-115//ASSP///
WPF/PL-AL/F-AL/PL-B12/F-B12
LED Installation (BTR Units only)
Step 1:
Take LED cable assembly out of Krown-X-X Plenum.
Step 2:
Remove well nut in center port of BTR filter.
Step 3:
Remove threaded standoff and lock washer from LED cable assembly.
Step 4:
Thread cable through static pressure port on face of BTR filter.
NOTE:
It is recommended to rest the filter frame on 2x4 lumber to protect the LED light from breaking.
Threaded Standoff
Lock Washer
Rubber Washer
Metal Washer
LED
LED Threaded Standoff
Filter Position for LED Installation
Static Pressure Port
Cable Assembly
For more information visit
KeystoneCleanAir.com
v001
16
Kr
own
Fan Filter Units |
Installation Instructions