Keysight CXG, EXG, and MXG X-Series Signal Generators Programming Guide 187
Programming the Status Register System
Status Groups
Data Questionable Status Group
The Data Questionable Status Group is used to determine the specific event
that set bit 3 in the Status Byte Register. This group consists of the Data
Questionable Condition Register, the Data Questionable Transition Filters
(negative and positive), the Data Questionable Event Register, and the Data
Questionable Event Enable Register.
Data Questionable Condition Register
The Data Questionable Condition Register continuously monitors the hardware
and firmware status of the signal generator. Condition registers are read only.
Some of the bits in this status group do not apply to all models, and return zero when queried.
See
for more information.
NOTE:
Some signal
generator
models may
use only a
subset of
the status
registers
shown.