35
–
Z5623AH84
Pulsed S-parameter test set, 2 to 40 GHz
Includes two pin switches for bi-directional (forward and reverse)
pulsed-RF stimulus, and two directional couplers for the reference
channels. It does not include internal amplifiers, but has front panel
access loops for switching in external amplifiers to boost port power
in both directions.
–
Z5623AH86
Pulsed S-parameter test set, 2 to 40 GHz
Includes one pin switch to modulate the analyzer’s internal source
in the forward direction, and one directional coupler for the refer-
ence channel. It does not include internal amplifiers, but has front
panel access loops for switching in an external amplifier to boost
port power.
–
Z5623AH87
Pulsed S-parameter test set, 1 to 50 GHz
Includes two pin switches for bi-directional (forward and reverse)
pulsed-RF stimulus. It does not include internal amplifiers, but has
front panel access loops for switching in external amplifiers to boost
port power in both directions.
–
Z5623AH89
Pulsed S-parameter test set, 10 MHz to 5 GHz
Includes one pin switch to modulate the analyzer’s internal source
in the forward direction. This test set has no internal amplifier, no
reference channel variable attenuator, and no GPIB control (manual
control only).
–
Z5623AH90
Pulsed S-parameter test set, 1 to 50 GHz
Same as Z5623AH87, but adds 50 GHz couplers to the front panel to
allow DUT connection on the test set instead of using the PNA test
ports.
Note: Pulse biasing can be achieved with or without the use of
a pulsed S-parameter test set. A proper pulse-bias driver must
be used. Contact your local Keysight Sales Representative
for additional pulsed S-parameter test set configurations and
details.
Peripherals
The following peripherals may be used with the Microwave
PNA Series. Other peripherals not listed here may also be
compatible with these instruments.
Monitors
VGA-compatible monitor
Printers
USB, LAN, parallel or serial printers with Microsoft Win-
dows printer driver
Interface cables
Choose the appropriate cables to connect each
peripheral to the network analyzer.
–
10833A
GPIB cable, 1.0 m (3.3 ft)
–
10833B
GPIB cable, 2.0 m (6.6 ft)
–
10833D
GPIB cable, 0.5 m (1.6 ft)
–
82357B
GPIB to USB interface
Applications
Material measurements
–
85070E
High-Temperature Dielectric Probe Kit
The 85070E enables measurements of the dielectric properties of
materials quickly and conveniently. Measurements made with this
probe are nondestructive and require no sample preparation. The
dielectric probe is well suited for measurements of liquid, semisolid
and flat solid materials. Measurement results can be viewed in a
variety of formats (ε’r, ε”r, tan δ or Cole-Cole). The supplied software
can be run in the PNA analyzer or on a PC.
–
85071E
Materials Measurement Software
The 85071E materials measurement software calculates the permitiv-
ity and permeability of material samples placed in a coaxial airline or
a rectangular waveguide. The measurement technique works well for
solid materials that can be machined to fit precisely inside a transmis-
sion line. Measurement results can be viewed in a variety of formats
(ε’r, εr, µ’r, µ”r, tan δ, or Cole-Cole µ). The software can be run in the
PNA analyzer or on a PC.
Pulsed measurements
1
The pulsed RF measurement capability (Option H08) and IF
access (Option H11), are recommended for pulsed measure-
ments with the PNA Series.
Pulse/pattern generators
Recommended to provide pulse signals and timing to the
pulsed S-parameter text set and MW PNA
–
81104A
Pulse/pattern generator, 80 MHz, single-/dual-channel
with one or two Keysight 81105A output modules.
–
81110A
Pulse/pattern generator, 165 MHz, single-/dual-channel
with one or two Keysight 81111A output modules.
Note: Each pulse/pattern generator must be ordered with its
associated output modules depending on the measurement
configuration.
Pulsed S-Parameter test sets
–
Z5623AH81
Pulsed S-parameter test set, 2 to 20 GHz
Includes a pin-diode switch to modulate the analyzer’s internal
source, an amplifier, and directional coupler to provide a pulsed
reference to the analyzer.
–
Z5623AH83
Pulsed S-parameter test set, 2 to 20 GHz
Includes two pin switches for bi-directional (forward and reverse)
pulsed-RF stimulus, and two directional couplers for the reference
channels. It does not include internal amplifiers, but has front panel
access loops for switching in external amplifiers to boost port power
in both directions.
1. For more details regarding pulsed measurement configurations with the PNA Series,
refer to Keysight’s Web site (
www.keysight.com/find/pna
) to download a copy
of the
Microwave PNA Series Network Analyzer Configuration Guide for Pulsed
Measurements
, literature number 5988-9833EN.