SATA Calibrations
4
Common Parameters for Calibrations
presents a description of the procedure parameters used in the
different calibrations.
Table 5
SATA calibration parameters
Parameter name
Parameter Description
Calibration
Embed Custom
Channel
Controls if a custom channel is embedded during
calibrations.
CIC Transfer Function
File
This shows the path to the transfer function file containing
the standard CIC definition for DUT calibrations. Only
visible if Embed Custom Channel is false. Read-only.
Custom Channel
Transfer Function File
This is the path to a user-created custom transfer function
file that will be embedded during calibrations. Only
available if Embed Custom Channel is true.
Custom C CIC
Transfer Function File
This is the path to a user-created custom transfer function
file that will be embedded during gen3 Host calibrations.
It should contain a transfer function definition that is
equivalent to adding the custom channel definition and
the standard CIC definition. Only available if Embed
Custom Channel is true.