Keysight N5991 SATA Test Automation Software Platform User Guide
77
Receiver Tests
5
• Min SSC Frequency: This is the minimum value of the SSC frequency to
be used for the procedure.
• Max SSC Frequency: This is the maximum value of the SSC frequency
to be tested.
• Number of SSC Frequency Steps: This is the number of different SSC
frequencies to be tested. The distribution of frequencies between
minimum and maximum is equidistant.
Data Generator
• Differential Voltage: The calibrated inner eye height at TP2.
• Random Jitter (RJ): The amount of calibrated RJ added to the signal.
• SJ Frequency: The frequency of the calibrated SJ added to the signal.
• Sinusoidal Jitter (SJ): The amount of calibrated SJ added to the signal.
• Data Rate Deviation: A fixed deviation from the nominal data rate.
Used Calibrations
• Random Jitter Calibration
• Sinusoidal Jitter Calibration
• Differential Voltage Calibration