Page 9
Find us at
www.keysight.com
PNA-X Series test set and power configuration options
1
(continued)
Test port 3
C
R3
Test port 1
R1
Test port 4
R4
Test port 2
R2
A
D
B
To receivers
LO
Pulse generators
Rear panel
1
2
3
4
Source 1
OUT 1
OUT 2
Pulse
modulator
Source 2
(standard)
OUT 1
OUT 2
Pulse
modulator
J9
J10
J11
J8
J7
J2
J1
J4
J3
35 dB
35 dB
35 dB
35 dB
65 dB
65 dB
65 dB
65 dB
J6
J5
RF
OUT
LO
OUT
R A B C D
IF inputs
4-port standard test set, power range and an
internal second source (Option 400)
The standard 4-port test set comes with 12 front-panel access
loops and a built-in second source. The loops provide access to
the signal path between (a) the source output and the reference
receiver, (b) the source output and directional coupler thru arm
and (c) the coupled arm of the directional coupler and the port
receiver. The internal second source provides an additional signal
(fixed or swept) for two-tone third-order-intercept (TOI) and
intermodulation testing of amplifiers, or it can be used as a fast
swept-LO signal for fixed-IF testing of mixers and converters.
With two sources, source 1 is accessible through test ports 1
and 2, and source 2 is accessible through test ports 3 and 4.
The standard test set also includes a solid-state internal RF
transfer switch in the R1 reference-receiver path. Option 080 is
recommended.
High-power configurable and extended power
range (N524xAS Option H85/485)
With extended power range and bias-tees (Option 419), the
internal bias-tees limit the maximum test port input power to
+30 dBm. The N524xAS Option H85/485 removes the bias-tees
between the source attenuators and the test port couplers. This
extends the maximum port power that the analyzer can safely
handle to +43 dBm. Selecting Option H85/485 adds internal at-
tenuators and cables. The N524xAS Option H85/485 and Option
419 can not be ordered together. Option H85/485 is not available
for the N5249A or the N5247A. When ordering, select N524xAS
then add items N524xAS-H85, N524xAS-485 and N524xA-400.
Test port 3
C
R3
Test port 1
R1
Test port 4
R4
Test port 2
R2
A
D
B
Source 2
OUT 1
OUT 2
Pulse
modulator
Source 1
OUT 1
OUT 2
Pulse
modulator
Pulse generators
To receivers
LO
R A B C D
IF inputs
Rear panel
Extended power range and bias-tees
(Option 419)
Adds to the standard test set one 65 dB for N5241/42/49A, 60 dB
for N5244/45A, and 50 dB for N5247A source attenuator (set-
table in 5 dB increments for N5241/42/49A and 10 dB increments
for N5244/45/47A), one 35 dB receiver attenuator (settable in
5 dB increments) for N5241/42/44/45/49A and 50 dB receiver
attenuator (settable in 10 dB increments) for N5247A, and one
bias-tee to each test port. Option 419 requires Option 400.
Add an internal combiner and mechanical
switches to 4-port analyzer (Option 423)
Available with 4-port model only, this option adds a combiner
and mechanical switches. The mechanical switches provide
increased flexibility by having rear panel access (front panel
access for the N5247A Source 1 and 2 Out 1) to signal paths for
advanced applications. Requires Options 400, 419 and 080.
Test port 3
C
R3
Test port 1
R1
Test port 4
R4
Test port 2
R2
35 dB
65 dB
35 dB
65 dB
65 dB
35 dB
65 dB
A
35 dB
D
B
Source 2
OUT 1
OUT 2
Pulse
modulator
Source 1
OUT 1
OUT 2
Pulse
modulator
Pulse generators
To receivers
LO
R A B C D
IF inputs
Rear panel
C
R3
R1
R4
R2
35 dB
65 dB
35 dB
65 dB
65 dB
35 dB
65 dB
A
35 dB
D
B
OUT 1
OUT 2
Pulse
modulator
OUT 1
OUT 2
Pulse
modulator
To receivers
LO
R A B C D
IF inputs
Rear panel
Source 1
Source 2
Test port 1
Test port 3
Test port 2
Pulse generators
Test port 4
1 The block diagrams shown above include hardware that must be ordered
as separate options, such as pulse generators (Option 025), pulse modu-
lators (Options 021 and 022), and IF access (Option 020). In addition, the
combiner type and attenuator values vary by model number. Refer to the
product data sheet for the correct block diagram for a specific model.