13
12
›
However,
future software updates
will enable flexible I/O configuration per port
›
IMPORTANT:
Each I/O port has a specific multicast group ID number assignment
»
Multicast group ID numbers are assigned using the web control interface.
»
See the Web Control Interface section for more information
»
Pair desired IR In or RS-232 RxD ports with desired IR Out or RS-232 TxD port
by assigning the same multicast group ID number.
»
IR In or RS-232 RxD at each I/O port must have a unique multicast group ID
number assignment.
»
Example:
Installation
Install up to eight units in an equipment rack using KD-RK120PLT. KD-RK120PLT also
houses Enterprise AV Tx or Rx units.
Mode 4: Control Extension via IP
›
KD-CX800 can be used to carry IR, RS-232, or voltage trigger over the network
›
It can be configured as point-to-point with or without a network switch:
›
Future software updates
will enable network-based control distribution/matrix
blocks to be created using many units:
›
Currently, I/O configurations are fixed (non-adjustable) as follows:
»
I/O Port 1: (Default) IR In (sensor or serial IR), or trigger In
»
I/O Port 2: (Default) IR out, or trigger out
»
I/O Port 3: RS-232