23
22
GetCFG:
<port#>
<port#>: Multi-function I/O
port number
Get I/O Port Configuration
Ex: GetCFG:1\r
Parameters
All parameters that may be part of a configuration command or a control or
configuration response.
Command
Field
Parameter
Possible Value
<port>
Port number
1: KD-CX800 I/O Port 1.
2: KD-CX800 I/O Port 2.
3: KD-CX800 I/O Port 3.
<br>
RS-232 baud rate
Baud rates supported by
KD-CX800 RS-232
mode are: 2400, 4800,
9600, 19200, 38400,
57600,115200.
<char length>
RS-232 character length
5:
Character length is 5 bits.
6:
Character length is 6 bits.
7:
Character length is 7 bits.
8:
Character length is 8 bits.
SetTR:
<port#>,
<time interval>
<port#>: Multi-function I/O
port number
<time interval>: Frequency
in milliseconds that the I/O
port will return current voltage
state. More info in the notes
section.
Set I/O Port to Trigger Mode
Ex: SetTR:3,1000\r
SetTCPC:
<tcp port#>
<TCP port#>: Desired TCP
port number for configuration
port
Sets the configuration port for
KD-CX800
Ex: SetTCPC:4766\r
SetTCPP:
<port#>,<TCP
port #>
<port#>: I/O port (1 – 3)
<TCP port#>: Desired TCP
port number
Sets the TCP port number for
specified I/O port
Ex:
SetTCPP:1,4767
TRO:
<port#>,
<level>
<port#>: Multi-function I/O
port number
<level>: HIGH, LOW
Set I/O Port Trigger Output
High or Low
Ex: TRO:2,HIGH
GetRS:
<port#>
<port#>: Multi-function I/O
port number
Get I/O Port RS-232
Configuration
Ex: GetRS:3\r
GetTR:
<port#>
<port#>: Multi-function I/O
port number
Get I/O Port Trigger State
Ex: GetTR:2\r
TRIN:
<port#>
<port#>: Multi-function I/O
port number
Get I/O Port Trigger Input
Level
Ex: TRIN:3\r