PRE-INSTALLATION
Note:
-
Products are connected end-to-end via the integrated connectors at each end of the product.
Note that there is an “input” and “output” connecter on each product and orientation is critical.
A common mistake made is to install the products backwards. Jumper cables may be inserted in
between fixtures in order to make installation easier.
-
50 ft leader cable max
-
40 ft of G2 Linear fixtures
-
100 ft total run max, including leader cable, fixtures, and jumper cables
A typical installation includes:
• N3 Satellite
• Leader cable with terminator
• 1 to 40 G2 linear fixtures
• Optional jumper cables as needed
• The G2 has mounting feet that have one thru hole on each side
• Attach the product to a flat surface using appropriate #8, #9, or #10 countersunk fasteners (e.g. wood
screws, sheet metal screws.)
PAGE 8
770-0000XX-0X-0X
G2
INSTALLATION GUIDE
•
The G2 has mounting feet that have one thru hole on each side.
•
Attach the product to a flat surface using appropriate #8, #9, or
#10 countersunk fasteners (e.g. wood screws, sheet metal screws .)
•
50 foot leader cable max
•
40 feet of G2 Linear fixtures
•
100 feet total run max, including leader cable, fixtures, and jumper cables
A typical installation includes:
•
N3 Satellite
•
Leader cable with terminator
•
1 to 40 G2 Linear fixtures
•
Optional jumper cables as needed
•
Products are connected end-to-end via the integrated connectors at each
end of product. Note that there is an “input” and “output” connecter on each
product and orientation is critical. A common mistake made is to install the
products backwards. Jumper cables may be inserted in between fixtures in
order to make installation easier.
3
G2
G2J
120VAC, 60 Hz
MAINS SUPPLY
G2
G2
G2
G2L
L1
OUT
IN
KETRA N3
G2 TO G2
DETAIL VIEW
INPUT
OUTPUT
G2
INPUT
G2 LEADER CABLE
OUTPUT
G2 LEADER CABLE TO G2
DETAIL VIEW
SIGNAL
GROUND
NEUTRAL
LINE
G2
120VAC, 60 Hz
MAINS SUPPLY
G2
L1
G2
G2
STAR TOPOLOGIES ARE NOT SUPPORTED
KETRA N3
G2L
L1
12 AWG, 3 WIRE
G2L
G2J
KETRANET MESH
WIRELESS NETWORK
KEY
KETRA G2 LEADER CABLE
KETRA G2 JUMPER CABLE
G2 LEADER CABLE
INPUT
N3 TO G2 LEADER CABLE
DETAIL VIEW
SIGNAL
GROUND
NEUTRAL
LINE
D+
COM
COM
COM
COM
+
+
+
1
2
3
4
+
–
+
Analog I/O
DC Out
B
A
A
B
Activity
L
N
S
Power & Signal OUT
N3 POWER & SIGNAL
OUTPUT
GENERAL NOTES:
1. KETRANET MESH IS KETRA'S WIRELESS
CONTROL PROTOCOL.
2. A NODE IS A KETRANET MESH ENABLED
WIRELESS DEVICE.
3. 50 KETRANET MESH NODES MAX. PER
INSTALLATION NETWORK.
4. ALL KETRANET MESH NODES TO BE
INSTALLED WITHIN 50'-0" RANGE OF THE
NEAREST NODE.
5. PER N3: MAX. FIXTURE QTY: 40FT OF G2
MAX. RUN LENGTH: 100FT
3815 S. CAPITAL OF TEXAS HWY
SUITE 100
AUSTIN, TX 78704
P: 512.347.1100
DRAWN BY:
DATE:
SHEET NAME
SHEET
SCALE:
CHECKED BY:
OF
FOR REFERENCE ONLY
NOT FOR
CONSTRUCTION
DRAWING #:
REVISION #:
DRAWING TYPE:
1
1
KETRA N3 TO G2
NTS
CEH
GEB
04/11/2016
00
OL
PRE-INSTALLATION
fig. 4
8 |
G2
INSTALLATION GUIDE
770-000003-01 r09