Included Components/Specs
Specifications
G2 linear unit
G2 System Components Include:
N3 Satellite
G2 Leader Cable
Terminator
G2 Jumper Cables as Needed
Environmental
Operating Temperature
-20˚ to 40˚C
Storage Temperature
-20˚ to 80˚C
Humidity
0 - 95%, Non-condensing
Certification
UL, cUL, FCC Class B, RoHS
Location
UL Damp Location, IP20
Power
Voltage
120 V , 60Hz
277 V , 60Hz
Power Consumption
G2.10 15.5 W/ft (304.8 mm)
G2.07 11 W/ft (304.8 mm)
G2.04 7.7 W/ft (304.8 mm)
Current at 220V
G2.10 0.07 A
G2.07 0.05 A
G2.04 0.04 A
Max. Qty of Fixtures Per N3
40
Max Total Run Length,
including cable, per N3
100 ft (30.48 m)
Optical
Lumen Output
G2.10 1000 lm/ft
G2.07 700 lm/ft
G2.04 400 lm/ft
CRI
>90
Lumen Maintenance
50K Hours to
L70 at 25 °C Ambient
Beam Angles
10x60°, 30x45°,
60x60°, 120x120°
Dimming Range
0.1-100% lm output
Electrical
Weight
1.35 lbs, 600 g
Housing Material
Powder Coated Aluminum,
Polymer
Lens Material
Non-yellowing heat/ UV
stabilized PMMA
PAGE 5
770-0000XX-0X-0X
G2
INSTALLATION GUIDE
G2 LINEAR UNIT
TERMINATOR
G2 SYSTEM
COMPONENTS INCLUDE
N3 SATELLITE UNIT
G2 LEADER CABLE
G2 JUMPER CABLES
AS NEEDED
BK: Black
AU: Aura 038: Par 3
8
NS: Narrow Spot
SP: Spot
FL: Flood
Series
Beam Angle
2: Japan - 100
V, 50/60 H
z
1: NA - 120V
, 60 Hz
SL: Silver
WH: White G: GU2
4
E: E2
6
Region
Size
Housing Color
Base
770-000003-01-28
© 2016 Ketra, Inc. All rights reserved.
Designed in Austin, Texas
+
1.512.347.1100
|
www.ketra.com
Specifications are subject to change without notice.
G2 HIGH OUTPUT LINEAR ACCENT
Project:
Comments:
Prepared By:
Optical Performance
Lumen Output
2
G2.10 1000lm/ft,
G2.07 700lm/ft,
G2.04 400lm/ft
CRI
>90
Lumen Maintenance
3
50K Hours to L70@25°C Ambient
Color Spatial Uniformity
<2 MacAdam ellipses across field angle
Color point maintained to <1 MacAdam ellipse over product lifetime
Beam Angles
10x60°, 30x45°, 60x60°, 120x120°
Dimming Range
0.1-100% lm output
Mechanical
Weight (12”)
1.35 lbs, 600 g
Housing Material
Powder Coated Aluminum, Polymer
Lens Material
Non-yellowing heat/ UV stabilized PMMA
Electrical
Power Consumption
G2.10 19W/ft TYP,
G2.07 12W/ft TYP,
G2.04 7W/ft TYP
Power Factor
>0.9
Current
G2.10 0.16 A
G2.07 0.1 A
G2.04 0.06 A
Efficacy
G2.10 53lm/W TYP,
G2.07 60lm/W TYP,
G2.04 57lm/W TYP
Max. Qty of Fixtures Per N3
40
Max Total Run Length, including cable, Per
N3
100ft
Accessories
Leader 50’, White (with Terminator)
G2L6001CWH
Leader 50’, Black (with Terminator)
G2L6001CBK
Leader 10’, White (with Terminator)
G2L1201CWH
Leader 10’, Black (with Terminator)
G2L1201CBK
Lead Out 10’, White
G2LO1201CWH
Lead Out 10’, Black
G2LO1201CBK
Jumper 1’, White
G2J0121CWH
Jumper 1’, Black
G2J0121CBK
Jumper 5’, White
G2J0601CWH
Jumper 5’, Black
G2J0601CBK
Jumper 10’, White
G2J1201CWH
Jumper 10’, Black
G2J1201CBK
Jumper 25’, White
G2J13001CWH
Jumper 25’, Black
G2J3001CBK
Terminator (Optional Replacement)
GTC
G2 Hex Louver, White (NFL, FL, WFL)
G212AHEXLUVWH
G2 Hex Louver, Black (NFL, FL, WFL)
G212AHEXLUVBK
G2 Alignment Track
G2TRKZP48
N3 Satellite
N3INDREC1BK
Environmental
Ambient Operating Temperature
-20 to 50°C
Storage Temperature
-20 to 80°C
Humidity
0 - 95%, Non-condensing
Certification
UL, cUL, RoHS
Location
UL Damp Location, IP20
Specifications
1
1
All performance measurements taken with fixture stabilized at 25°C ambient, 100% power input, unless otherwise stated, within CCT range of 2700 - 5000K.
2
Lumen measurement complies with IES LM-79-08 testing procedures.
3
Lumen maintenance values calculated in accordance to TM-21 procedures based on LM-80 compliant measurement data.
Form Factor
Dimensions:
Beam Angle:
Dim A
Dim B
Dim C
Wide Flood
12”, 305 mm
2”, 50.8 mm
2.5”, 63.5 mm
Flood
2.5”, 63.5 mm
Narrow Flood
2.65”, 67 mm
Graze
3.1”, 78.7 mm
Rotation
Infinite adjustment through 180°
A
B
C
A
B
C
CONTENTS
SPECIFICATIONS
5 |
G2
INSTALLATION GUIDE
770-000003-01 r09
© 2019 Ketra, Inc. All rights reserved