background image

Risk of electric shock. Use in dry locations only.

Turn power OFF at circuit breaker or remove fuse. Damage to this product caused by wiring with power 
on voids the warranty.

Due to the risk of electric shock, a licensed electrician should install this power supply unit in strict 
compliance with the National Electrical Code and any state or local code which may apply. 

This device complies with Part 15 of the FCC Rules. Operation is subject to the  
following two conditions: ( 1 ) this device may not cause harmful interference, and ( 2 ) this device must 
accept any interference received, including interference that may cause undesired operation. 

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 
harmful interference in a residential installation. This equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful 
interference to radio communications. However, there is no guarantee that interference will not occur 
in a particular installation. If this equipment does cause harmful interference to radio or television 
reception, which can be determined by turning the equipment off and on, the user is encouraged to try 
to correct the interference by one or more of the following measures:

•  Reorient or relocate the receiving antenna.

•  Increase the separation between the equipment and receiver.

•  Connect the equipment into an outlet on a circuit different from that to which the receiver  

is connected.

•  Consult the dealer or an experienced radio/TV technician for help

This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and 
Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following  
two conditions:

•  This device may not cause interference.

•  This device must accept any interference, including interference that may cause undesired 

operation of the device.

!

Warning

2 | 

G2

 INSTALLATION GUIDE

770-000003-01 r09

© 2019 Ketra, Inc. All rights reserved

Summary of Contents for G2 Series

Page 1: ...odel G21210BTGR33AWH BK G21210BTNFL33AWH BK G21210BTFL33AWH BK G21210BTWFL33AWH BK G21207BTGR33AWH BK G21207BTNFL33AWH BK G21207BTFL33AWH BK G21207BTWFL33AWH BK G21204BTGR33AWH BK G21204BTNFL33AWH BK G21204BTFL33AWH BK G21204BTWFL33AWH BK ...

Page 2: ...f not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the inte...

Page 3: ...n 10 Connect Fixtures 10 Attach Terminator 10 Connect Leader Cable 10 Apply Power at Source 11 Verify Successful Installation 11 Aim Fixtures 12 Address Fixtures and Program Content 12 Troubleshooting 13 Warranty Tech Support 14 3 G2 INSTALLATION GUIDE 770 000003 01 r09 2019 Ketra Inc All rights reserved ...

Page 4: ...Product Overview fig 1 G2 power signal input G2 power signal output 4 G2 INSTALLATION GUIDE 770 000003 01 r09 2019 Ketra Inc All rights reserved ...

Page 5: ...intained to 1 MacAdam ellipse over product lifetime m Angles 10x60 30x45 60x60 120x120 ming Range 0 1 100 lm output hanical ht 12 1 35 lbs 600 g ing Material Powder Coated Aluminum Polymer Material Non yellowing heat UV stabilized PMMA Electrical Power Consumption G2 10 19W ft TYP G2 07 12W ft TYP G2 04 7W ft TYP Power Factor 0 9 Current G2 10 0 16 A G2 07 0 1 A G2 04 0 06 A Efficacy G2 10 53lm W ...

Page 6: ...l process Installation instructions may change without notice due to continuous improvements Do not use product if it is damaged Fixtures contain no user serviceable parts Do not connect product to any voltage or frequency supply other than that for which it is rated Rated for direct insulation contact If placed in enclosure alongside other electrical components take necessary precautions regardin...

Page 7: ...or the N3 Satellite for more details Each N3 Satellite can support up to 40 ft 12 19 m of product For longer run lengths use additional N3 Satellites for each 40 ft 12 19 m or less of product N3 Satellites can be connected to the same power source and do not each require a dedicated circuit Connect all product in a single run from the N3 Satellite Home Run style installations are not supported Hom...

Page 8: ...eded Products are connected end to end via the integrated connectors at each end of product Note that there is an input and output connecter on each product and orientation is critical A common mistake made is to install the products backwards Jumper cables may be inserted in between fixtures in order to make installation easier 3 G2 G2J 120VAC 60 Hz MAINS SUPPLY G2 G2 G2 G2L L1 OUT IN KETRA N3 G2...

Page 9: ...e top of the control board cover see fig 5 fig 5 fig 6 AC Mains IN TRIAC Control LN L N Power Signal OUT S N L Activity Status Monitor B A DMX DALIT RIAC Power A B DC Out DALI DMX Out DMX In Analog I O 4 3 2 1 COM COM COM COM D D D GND GND D SN KD00000016 DC K3914 OC N3INDREC1BK The product can be rotated 180 degrees to enable aiming the beam Note that when rotated the overall height and width of ...

Page 10: ...eader Cable 1 One end of the leader cable has a connector and the other end has flying leads The connector end of the leader cable connects to the first product in the run The flying leads end of the leader cable connects to the output side of the N3 Satellite Note that the leader cable can be cut to length 2 Make the connections to the N3 Satellite Use Ketra supplied G2 leader cable or if require...

Page 11: ...iate line neutral and ground terminals Note wire strip length is 12mm 47inches Insert appropriate conductors from Mains Power see fig 6 Black conductor goes to L terminal White conductor goes to N terminal Green conductor goes to terminal Red conductor goes to S terminal Note Conductor colors are not always as listed These colors vary depending on your wiring setup To ensure the correct wiring con...

Page 12: ... not require any locking mechanism 3 Optional Tighten the locking screws at the end of each fixture using a T10 torx wrench or 2mm Hex wrench STEP 7 Address Fixtures and Program Content 1 Use Ketra s Design Studio Software to address and configure the products 12 G2 INSTALLATION GUIDE 770 000003 01 r09 2019 Ketra Inc All rights reserved ...

Page 13: ...S port Red Green Blue Pattern Line and neutral wiring switched Cut power and reverse line and neutral wiring Red Green Pattern Line and neutral wiring switched Cut power and reverse line and neutral wiring Yellow Multiple runs of linear product detected Cut power and disconnect all but one run of G2 Only one run can be connected to a satellite Turquoise More than 40 ft 12 19 m of linear product de...

Page 14: ...y For questions and technical support please contact 844 588 6445 ketrasupport lutron com Ketra and KetraNET are trademarks or registered trademarks of Lutron Ketra LLC in the US and or other countries 14 G2 INSTALLATION GUIDE 770 000003 01 r09 2019 Ketra Inc All rights reserved ...

Page 15: ...15 G2 INSTALLATION GUIDE 770 000003 01 r09 2019 Ketra Inc All rights reserved ...

Page 16: ...6231 E Stassney Ln Bldg 13 Suite 400 Austin TX 78744 ketra com 512 872 4349 770 000003 01 r08 ...