4.1 Working conditions
Readiness for operation
Power
-LED
green
lit
off
Alarm
-LED
red
off
blinks (1 sec. Takt)
Backwater
Flap closes
Power-LED
green
lit
off
Alarm-LED
red
off
off
Backwater-LED orange
blinks
off
FlapLED
orange
blinks
blinks (1 sec. Takt)
Flap is closed
Power-LED
green
lit
off
Alarm-LED
red
off
off
Backwater-LED orange
blinks
blinks
Flap-LED
orange
lit
off
Acoustic Alarm
Acoustic Alarm
Acoustic Alarm
The alarm can be acknowledged with the test key, i.e. the
alarm signal is switched off during the backwater.
In mains operation, this is indicated by the alarm LED flas-
hing. All the other optical displays do not change.
In battery operation, the backwater is indicated by the
backwater LED flashing every second, all other optical dis-
plays remain dark.
Mains operation
Battery operation
4. Operating the Standard control unit
4.2 Function keys
Alarm key
The alarm can be acknowledged by pres-
sing the alarm key. The alarm-LED flas-
hes and thus indicates to the operator that
the fault is still pending.
Test key (TEST)
The operating valve can be actuated ma-
nually e.g. for maintenance purposes.
The flap is closed by pressing it once.
The flap is opened again if pressed a se-
cond time.
Closing and opening of the flap is indica-
ted by flashing, the closed flap by the flap
LED lighting up. When the flap is closed,
an acoustic signal (alarm) is given.
Caution: flap does not open automati-
cally!
If backwater occurs while the flap is clo-
sing, this is indicated by the backwater
LED flashing as soon as the flap has been
closed completely.
Caution:
The end of the backwater is in-
dicated by the backwater LED going out
(optical indication only!). The alarm tone
no longer changes.
During backwater the flap cannot be ope-
ned manually.
Caution:
The end of the backwater is in-
dicated by the backwater LED going out
(optical indication only!). The alarm tone
no longer changes.
The flap can be opened again using the
test key.
The test key cannot be activated in bat-
tery operation in order to go easy on the
batteries!
4.3 Putting the unit out of operation
Caution:
After the mains plug has been
disconnected, the alarm key
must be pressed for at least 5 seconds
until the signal is sounded. This is to go
easy on the battery
010-845EN_FKA_Schaltgerät_2011_03_010-131 Stand 10-07_AKTUELL2008.qxd 25.10.11 10:32 Seite 7
Summary of Contents for Staufix FKA Comfort
Page 22: ...22 Notizen...
Page 23: ...23 Notizen...
Page 25: ......
Page 27: ......
Page 53: ...010 845EN_FKA_Schaltger t_2011_03_010 131 Stand 10 07_AKTUELL2008 qxd 25 10 11 10 32 Seite 25...
Page 55: ...010 845EN_FKA_Schaltger t_2011_03_010 131 Stand 10 07_AKTUELL2008 qxd 25 10 11 10 32 Seite 27...
Page 78: ...78 Note...
Page 79: ...Note 79...