2.4 Probe connection
The optical probe is mounted in the FKA
locking cover. For this purpose, the blind
plug (lilac) is removed and the probe is
screwed in place using the enclosed scr-
ews (2 M5 x 12 screws (TX25).
2.5 External signal generator
The external signal generator (order no.
20162) for transmitting the acoustic war-
ning to other rooms can be connected if
required
2.6 Potential-free switch contact
As an option, an additional board with a
potential-free contact (order no. 80072)
can be connected to the central control
technology of the building. For connection
see the leaflet on potential-free contact. In
the event of backwater or a problem,
every alarm is sent via the potential-free
contact. During flap test (key function “flap
test”) an alarm is given via the potential-
free contact when the flap reaches the
final position “closed”.
2.7 Extending the control cables
If more than 5 m cable is required, 10 m
extensions are available (art. no. 80889
probe, art. no. 80890 motor).
The maximum cable length of 30 m must
not be exceeded.
2. Electrical connection
Fig. 5
2.8 Connection diagram Standard control unit
1 2 3 1 2 3
2.9 Connection diagram Comfort control unit
010-845EN_FKA_Schaltgerät_2011_03_010-131 Stand 10-07_AKTUELL2008.qxd 25.10.11 10:31 Seite 5
Summary of Contents for Staufix FKA Comfort
Page 22: ...22 Notizen...
Page 23: ...23 Notizen...
Page 25: ......
Page 27: ......
Page 53: ...010 845EN_FKA_Schaltger t_2011_03_010 131 Stand 10 07_AKTUELL2008 qxd 25 10 11 10 32 Seite 25...
Page 55: ...010 845EN_FKA_Schaltger t_2011_03_010 131 Stand 10 07_AKTUELL2008 qxd 25 10 11 10 32 Seite 27...
Page 78: ...78 Note...
Page 79: ...Note 79...