KLP070312
3-25
• To set DHCP to ON, enter an IP ADDRESS of 0.0.0.0, then highlight the desired unit
and click the Set button. After a few seconds, click Search Again, highlight the desired
unit and click the Set button.
The Baudrate pull-down menu and Advanced button are provided for debug of the unit, provid-
ing access to some internal registers of the interface. Changes in these registers may cause the
unit to become inoperative until power up of the unit occurs. These changes are only temporary,
and are overwritten when the next time the KLP is powered up.
FIGURE 3-4. SETTING A STATIC IP ADDRESS
3.3.6.3
LAUNCH WEB INTERFACE [E-SERIES MODELS ONLY]
After running the PSfind utility (see PAR. 3.3.6.2), click the Launch Webpage button to open the
KLP Instrument HOME PAGE (UNIT DESCRIPTION) in your default browser (see Figure 3-5).
You can also launch the web page in any browser by entering the IP address as the URL.
NOTE: If source power to the KLP is removed or lost while a browser window is open, commu-
nication with the KLP can not be restored until the present browser window is closed
and a new window is opened.
Upon initial display of the web page, it is good practice to click the browser Refresh/Reload but-
ton once to ensure that the power supply information displayed is up to date, and not prior infor-
mation recalled from the browser cache.
Although most current browsers will work, Kepco recommends the following as fully supported:
IE 5.5 and higher, Netscape 6 and higher and Firefox 1.0 and higher. Popup blocking must be
disabled and Javascript must be enabled for proper operation. If popup blocking is enabled, it
may prevent viewing of the help screens.
The KLP Instrument Home page identifies the unit which has been accessed, including Manu-
facturer, Instrument, Description, Serial Number, Calibration Date, LXI Software Revision, LXI
Class, LXI Version, Hostname, MAC Address and TCP/IP Address. Click the HELP box at the
left of the screen for detailed explanations of each. These parameters can not be changed by
the user. Fault alerts are not available from this page.
Clicking the ID INSTRUMENT box at the left of the screen, causes the physical front panel LAN
indicator on the selected unit to blink, allowing visual confirmation as to which unit is selected.
This is especially important if more than one unit is found on the LAN.
Summary of Contents for KLP 10-150-2
Page 2: ......
Page 6: ......
Page 12: ...vi KLP070312 FIGURE 1 1 KLP SERIES POWER SUPPLY...
Page 19: ...KLP 070312 1 7 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2...
Page 20: ...1 8 KLP 070312 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Page 27: ...KLP HV 070312 2 3 FIGURE 2 2 KLP SERIES REAR PANEL SWITCH AND CONNECTORS...
Page 40: ......
Page 78: ......
Page 90: ......