3-20
KLP070312
FIGURE 3-2. FAULT RECOVERY CONFIGURATION DISPLAY
2. To change a fault recovery setting, tap the
DC OUTPUT
switch to enter the Recovery menu.
3. The status display shows
PASS
. Enter the unit password (see PAR. 3.2.7) and tap
DC OUT-
PUT
switch to accept the number. When the password is accepted, status display reads
OVP
and the
DC VOLTS
display shows the present fault recovery status (
PROT
or
SAFE
) for
OVP
.
Rotate either
VOLTAGE
or
CURRENT
control to cycle through
OVP
,
OCP
,
OLF
,
TEMP
, and
PWR
settings. To exit tap the
DC OUTPUT
switch while the status display shows
RTN
.
4. To change a setting, tap the
DC OUTPUT
switch while the status display shows the fault.
The setting in the
DC VOLTS
display begins to blink. Rotate either
VOLTAGE
or
CURRENT
control to cycle through the allowable settings. Tap the
DC OUTPUT
switch to accept the
setting shown in the
DC VOLTS
display.
5. To continue, rotate either
VOLTAGE
or
CURRENT
control to select another fault. To exit,
either select
RTN
and tap the
DC OUTPUT
switch to go to the next highest menu, or tap the
FUNCTION
switch to exit function mode.
3.2.16.4 ANALOG OUTPUT FULL SCALE CALIBRATION
Enter
UTIL
menu (see PAR. 3.2.16, steps 1 through 3) and rotate either
VOLTAGE
or
CUR-
RENT
control until status display reads
ANRB
.
• The
DC VOLTS
display shows the analog readback voltage value that produces the full
scale output voltage as established by the virtual model.
• The
DC AMPS
display shows the analog readback voltage value that produces the full
scale output current as established by the virtual model.
1. To change the settings tap the
DC OUTPUT
switch. Note that
DC VOLTS
and
DC
AMPERES
displays begin blinking.
2. Rotate
VOLTAGE
control to set the analog readback voltage value desired for full scale out-
put voltage.
3. Rotate the
CURRENT
control to set the analog readback voltage value desired for full scale
output current.
4. Tap the
DC OUTPUT
switch to accept the new settings (blinking stops) or use a thin tool
(e.g., a paper clip) to press the
FUNCTION
switch to cancel the operation.
5. To exit, rotate either
VOLTAGE
or
CURRENT
control until the status display reads
RTN
, then
tap the
DC OUTPUT
switch. To exit the
UTIL
menu rotate either
VOLTAGE
or
CURRENT
control until the status display reads
EXIT
, then tap the
DC OUTPUT
switch.
NOTE:
THE FOLLOWING SETTINGS ARE SHOWN:
PWR SET TO AUTO
TEMP SET TO AUTO
OLF SET TO PROTECT
OCP SET TO PROTECT
OVP SET TO SAFE
Summary of Contents for KLP 10-150-2
Page 2: ......
Page 6: ......
Page 12: ...vi KLP070312 FIGURE 1 1 KLP SERIES POWER SUPPLY...
Page 19: ...KLP 070312 1 7 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 1 OF 2...
Page 20: ...1 8 KLP 070312 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Page 27: ...KLP HV 070312 2 3 FIGURE 2 2 KLP SERIES REAR PANEL SWITCH AND CONNECTORS...
Page 40: ......
Page 78: ......
Page 90: ......