3-12
KLP031308
the address, press
DC OUTPUT
switch, then rotate
VOLTAGE
control to change
192._
or
CURRENT
control to change
168._
, then press
DC OUTPUT
switch to save.
•
IP2
- Shows second half of IP address (e.g., for IP address 192.168.000.200 the
DC
VOLTS
display shows
_000
. and the
DC AMPERES
display shows
_200
). To change
the address, press
DC OUTPUT
switch, then rotate
VOLTAGE
control to change
_000
.
or
CURRENT
control to change
_200.
, then press
DC OUTPUT
switch to save.
•
MSK1
- Shows first half of SUBNET MASK address (see IP1 described above). Default is
255.255.
•
MSK2
- Shows second half of SUBNET MASK address (see IP2 described above).
Default is 0.0
•
GTE1
- Shows first half of GATE address (see IP1 described above).
•
GTE2
- Shows second half of GATE address (see IP2 described above).
•
DNS1
- Shows first half of DNS address (see IP2 described above).
•
DNS2
- Shows second half of DNS address (see IP2 described above).
•
RTN
- Return to
LAN
menu.
3.2.13
UTILITY FUNCTION
The Utility Function provides additional system information or access to special functions.
These are described below.
1. If the status display shows
SET
, tap either the
CURRENT
or
VOLTAGE
controls to take the
unit out of setpoint mode (status display goes from
SET
to blank)
2. Using a thin tool (e.g., a paper clip), press the
FUNCTION
switch once until the status dis-
play reads
VIRT
, then rotate either the
VOLTAGE
or
CURRENT
control in either direction
until status display reads
UTIL
.
3. Tap the
DC OUTPUT
switch once, then rotate either the
VOLTAGE
or
CURRENT
control in
either direction to select the function identified in the status display (see below).
•
VERS
- Display System Firmware Version (see PAR. 3.2.13.1)
•
MODL
- Display Model (see PAR. 3.2.13.2)
•
RELY
- Relay Control (see PAR. 3.2.13.3)
•
QkBT
- Quick Boot (see PAR. 3.2.13.4)
•
SYST
- System Configuration (see PAR. 3.2.13.5)
•
INVC
- Analog Input Voltage and Current A to D calibration voltages (see PAR. 3.2.13.6)
•
LBT
- [-1200 Models only] Loop Back Test used to isolate RS 232 communication prob-
Summary of Contents for KLP 10-150-1.2K
Page 2: ......
Page 6: ......
Page 12: ...vi KLP031308 FIGURE 1 1 KLP SERIES POWER SUPPLY...
Page 19: ...KLP 031308 1 7 FIGURE 1 3 KLP SERIES POWER SUPPLY MECHANICAL OUTLINE DRAWING SHEET 2 OF 2...
Page 24: ......
Page 27: ...KLP HV 031308 2 3 FIGURE 2 2 KLP SERIES REAR PANEL SWITCH AND CONNECTORS...
Page 40: ......