III — EQUIPMENT SUPPLIED

.

 

See Table 2.

IV — SAFETY. 

See Table 

3

V — PRELIMINARY OPERATIONAL CHECK.

A simple operational check after unpacking and
before equipment installation is advisable to ascer-
tain whether the power supply has suffered damage
resulting from shipping. 

1. With POWER switch set to off position, connect

the power supply to source power (see “Input
Connections.” on page 5.

2. With no load connected, set POWER switch to

the ON position. Each time the unit is turned on
an internal self-test is performed. If all tests pass,
the unit goes into the default mode. If a failure
occurs, the failure is displayed. Figure 5 shows
the factory-configured power on defaults dis-
played on the LCD.

3. Connect a digital voltmeter (DVM) (resolution and

accuracy of 0.01% or better) to the OUT S and
COM S terminals at the rear panel terminal block.

4. Use the keypad to enter the rated maximum volt-

age of the power supply (e.g., enter 36 for a
model BOP 36-28MG) and press 

ENTER

. If

STANDBY indicator is lit, press 

STANDBY

 key.

5. Verify DVM voltage reading agrees with pro-

grammed voltage within 0.03% of rated maximum
voltage and agrees with displayed voltage on
LCD within 0.05% of rated maximum voltage.

TABLE 1.  BOP 1KW-MG/ME MODEL PARAMETERS

Model 

(1)

d-c Output Range

Closed Loop Gain

Output Impedance

Voltage 

(2)

(V d-c)

Current

(A d-c)

Voltage 

Channel

G

V

 (V/V)

Current 

Channel

G

I

 (A/V)

Voltage Mode

(Series R - L)

Current Mode

(Parallel R - C)

R

d-c

(mOhms)

L

(

H)

R

d-c

(Ohms)

C

(

F)

1000 WATT MODELS

BOP 6-125MG/ME

0 to ±6

0 to ±125

0.6

12.5

0.05

1.5

24

1150

BOP 10-100MG/ME

0 to ±10

0 to ±100

1.0

10.0

0.1

2.0

50

1100

BOP 10-75MG/ME

0 to ±10

0 to ±75

1.0

7.5

0.13

2.0

67

976

BOP 20-50MG/ME

0 to ±20

0 to ±50

2.0

5.0

0.40

8.3

200

371

BOP 25-40MG/ME

0 to ±25

0 to ±40

2.5

4.0

0.63

15.8

313

165

BOP 36-28MG/ME

0 to ±36

0 to ±28

3.6

2.8

1.30

25

640

103

BOP 50-20MG/ME

0 to ±50

0 to ±20

5.0

2.0

2.50

50

1250

55

BOP 72-14MG/ME

0 to ±72

0 to ±14

7.2

1.4

5.14

104

2570

33

BOP 100-10MG/ME

0 to ±100

0 to ±10

10.0

1.0

10.0

163

5000

16

(1) Models with MG suffix include GPIB and RS 422 digital interfaces. Models with ME suffix include LAN and RS 422 digital interfaces.
(2)  When connecting active loads, the steady-state voltage of the active load must not exceed the maximum voltage rating of the BOP. 

Otherwise the overvoltage protection will shut down the power supply.

TABLE 2.  EQUIPMENT SUPPLIED

ITEM

FUNCTION

PART NUMBER

Source Power Entry 
mating connector

Mates with source power 
entry connector

 142-0381 
(Kepco) (IEC 
320)

PAR/SER CONTROL 
- IN mating connector

Mates with PAR/SER 
CONTROL - IN port to 
allow access to pins 
required for calibration

142-0488 
(Kepco)

TABLE 3.  SAFETY SYMBOLS

SYMBOL

MEANING

CAUTION: RISK OF ELECTRIC SHOCK.

CAUTION: REFER TO REFERENCED PROCE-
DURE.

WARNING

INDICATES THE POSSIBILITY OF BODILY 
INJURY OR DEATH.

CAUTION

INDICATES THE POSSIBILITY OF EQUIPMENT 
DAMAGE.

!

Summary of Contents for BOP 10-100MG/ME

Page 1: ...units the GPIB interface is replaced with a LAN interface Unless otherwise noted this guide applies to both models ACCESSING MANUALS First determine your Firmware Version see below then download the B...

Page 2: ...or current and a 1 to 10V input for the limit channels BOP models are suitable for driving inductive loads such as large magnets or motors and for exercising batteries They are also suitable for chara...

Page 3: ...el 1 d c Output Range Closed Loop Gain Output Impedance Voltage 2 V d c Current A d c Voltage Channel GV V V Current Channel GI A V Voltage Mode Series R L Current Mode Parallel R C Rd c mOhms L H Rd...

Page 4: ...4 228 1692 REV 8 090418 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 1 BOP OUTPUT CHARACTERISTICS...

Page 5: ...n to IEEE 1118 BITBUS port 142 0485 Kepco KMDLA 5P Kycon Inc IEEE 488 Cable 1 meter long For MG models only Connects BOP power supply to GPIB bus SNC 488 1 IEEE 488 Cable 2 meter long For MG models on...

Page 6: ...operation voltage or current output volt age or current and establish positive and negative voltage and current limits An output analog corre sponding to output current is also provided Refer to Oper...

Page 7: ...LS AND INDICATORS RS 232 CONNECTIONS Connect the BOP 1KW to a modem using a Null Modem patch cable at the RS 232 port located on the rear panel See Fig ure 3 A Null Modem cable is not required for old...

Page 8: ...1355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 3 BOP 1KW SERIES REAR PANEL VIEW LINKS INSTALLED FOR LOCAL SENSING FIGURE 4 LOAD CONNECTION A LOCAL...

Page 9: ...ng an item on the list and pressing the View Modify function key Menus and submenus will display a list of parameters with the top one high lighted The function key assignments can vary but generally...

Page 10: ...g and output Calibration Voltage Current and External and Controls calibration Shows Firmware versions for Display Serial GPIB LAN and analog Power up Settings Mode Voltage Cur rent External Main chan...

Page 11: ...channels one to set output voltage or current and one to set the corre sponding protection limit The main channel is deter mined by the MODE key in local mode which alternately selects either Voltage...

Page 12: ...ral Setup menu then highlight Max Min Set tings 2 Press to enter the Max Min Settings submenu Figure 6 If a Password is required see Opera tor s Manual for instructions 3 Highlight the voltage or curr...

Page 13: ...afety fea tures constant current type active electronic loads must be adjusted to zero and the BOP front panel LCD must read 0V minimum cur rent before handling the power supply to load connections Re...

Page 14: ...flow during the OFF state Table 5 indicates how the power supply responds to a command to go from Output ON to OFF CONFIGURE LOAD TYPE To configure press from the power up screen then highlight Load T...

Page 15: ...copower com email hq kepcopower com FIGURE 1 BOP 1KW OUTLINE DIMENSIONS SHEET 1 OF 2 20 000 508 00 21 439 544 54 22 800 579 11 21 564 547 73 22 000 558 79 23 863 606 12 18 235 463 16 18 985 482 21 1 4...

Page 16: ...FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 1 BOP 1KW OUTLINE DIMENSIONS SHEET 2 OF 2 SLIDES TRAVEL DISTANCE 23 000 584 2 22 000 5...

Reviews: