Pressing 

ADJUST

 while rotating adjusts the

least significant digit. If the output is on (unit
not in Standby) changes made using the

ADJUST 

control are immediately applied to

the output.

For alphanumeric characters use multiple
presses of the number keys for letters or sym-
bols: 

0

 (space), 

1

 (+, –, /), 

2

 (ABC), 

3

(DEF), 

4

 (GHI), 

5

 (JKL), 

6

 (MNO). 

7

(PQRS), 

8

 (TUV), 

9

 (WXYZ). Use the 

T

key to highlight the next character. As an alter-
native, the 

U

 or 

Y

 keys or 

ADJUST

 control

will scroll through numbers, and letters and
symbols. Use the 

CLEAR

 key to clear the

entire alphanumeric field and start over

3. Press 

$

 to apply the change and return to the

menu (to change another parameter, repeat steps
1 and 2). To abort (return to the menu without
applying the change), press 

%

 NOTE:Press 

HELP 

key for more information,

press 

HELP

 again to see multiple

screens; press 

CLEAR 

key to exit the

help screen.

ADJUSTING LCD BRIGHTNESS, CON-

TRAST AND BACKGROUND 

From the power-

up screen, (Figure 5), press 

#

 twice to initiate con-

trast adjustment. The contrast gradually alternates
between light and dark. When the contrast is accept-
able, press 

#

 to apply the change and exit contrast

adjust. Use the 

T

 and 

R

 keys for fine adjustment

of contrast. Contrast can also be adjusted from the
power-up screen by pressing 

#

 once, then press-

ing 

T

 and 

R

 as needed for fine adjustment. 

To change the background, press 

#

 from the

power-up screen, Highlight Background, press 

!

,

highlight Black or White, then 

$

 to save. Press 

$

exit and save for power-up or 

%

 to apply the

changes (without saving for power-up) and exit.

ENABLING/DISABLING AUDIBLE BEEPS 

From the power-up screen, press 

#

, then modify

the setting. Even though audible beeps are set to off,
the beeps will still sound upon power-up or detection
of a power supply fault.

SETTING VOLTAGE OR CURRENT MODE 

The BOP uses two separate channels, one to set
output voltage or current and one to set the corre-
sponding protection limit. The main channel is deter-
mined by the 

MODE

 key (in local mode) which

alternately selects either Voltage mode or Current

mode or by SCPI command (in digital remote mode).
The protection channel is determined automatically
by the main channel selected. When Voltage mode
is selected, the current protection channel is active,
and when Current mode is selected, the Voltage pro-
tection channel is active. 

PROGRAMMING VOLTAGE OR CURRENT 

AND ASSOCIATED PROTECT LIMITS 

 From

the power-up screen the settable voltage/current
parameters are displayed at the bottom of the LCD
above the 

HELP

 message. Use 

Y

 or 

U

 to highlight

the main or protect channel. 

1. To verify that the unit is configured for internal ref-

erences press 

$

 from the power-up screen and

verify that Reference Input and Protection Limit
are set to Internal, and External Mode is set to
Disable. If necessary to change a setting, use 

Y

or 

U

 to highlight the parameter, and press 

!

 to

modify. Highlight the desired selection and press

$

 to save, then press 

$

 to save for power-up

or 

%

 to exit. If analog programming is desired,

refer to Operator’s Manual.

2. Verify that the load type has been configured

properly to ensure that the unit behaves as
expected when the output is off (see “Max/Min
Setting Menu” on page 13 6 for details).

3. Press 

MODE

 key to select the main channel

(VOLTAGE or CURRENT); the associated PRO-
TECT channel is automatically selected and dis-
played. 

4. Set the output on or off as desired using the

STANDBY

 key. The output is off (disabled) when

the 

STANDBY

 indicator is lit, on (enabled) when

not lit. 

5. Use 

Y

 or 

U

 to highlight the main channel. There

are two ways to program the output in local mode.
These methods can be used either when the out-
put is disabled (

STANDBY

 indicator lit) or

enabled.

WARNING

When the ADJUST control is
rotated, the active parameter is
immediately effective if the output
is enabled (on = STANDBY indica-
tor not lit). The voltage/current
applied to the load changes as the
ADJUST control is rotated. 

Use the 

ADJUST

 control to increase or

decrease the main channel setting (e.g., volt-

Summary of Contents for BOP 10-100MG/ME

Page 1: ...units the GPIB interface is replaced with a LAN interface Unless otherwise noted this guide applies to both models ACCESSING MANUALS First determine your Firmware Version see below then download the B...

Page 2: ...or current and a 1 to 10V input for the limit channels BOP models are suitable for driving inductive loads such as large magnets or motors and for exercising batteries They are also suitable for chara...

Page 3: ...el 1 d c Output Range Closed Loop Gain Output Impedance Voltage 2 V d c Current A d c Voltage Channel GV V V Current Channel GI A V Voltage Mode Series R L Current Mode Parallel R C Rd c mOhms L H Rd...

Page 4: ...4 228 1692 REV 8 090418 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 1 BOP OUTPUT CHARACTERISTICS...

Page 5: ...n to IEEE 1118 BITBUS port 142 0485 Kepco KMDLA 5P Kycon Inc IEEE 488 Cable 1 meter long For MG models only Connects BOP power supply to GPIB bus SNC 488 1 IEEE 488 Cable 2 meter long For MG models on...

Page 6: ...operation voltage or current output volt age or current and establish positive and negative voltage and current limits An output analog corre sponding to output current is also provided Refer to Oper...

Page 7: ...LS AND INDICATORS RS 232 CONNECTIONS Connect the BOP 1KW to a modem using a Null Modem patch cable at the RS 232 port located on the rear panel See Fig ure 3 A Null Modem cable is not required for old...

Page 8: ...1355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 3 BOP 1KW SERIES REAR PANEL VIEW LINKS INSTALLED FOR LOCAL SENSING FIGURE 4 LOAD CONNECTION A LOCAL...

Page 9: ...ng an item on the list and pressing the View Modify function key Menus and submenus will display a list of parameters with the top one high lighted The function key assignments can vary but generally...

Page 10: ...g and output Calibration Voltage Current and External and Controls calibration Shows Firmware versions for Display Serial GPIB LAN and analog Power up Settings Mode Voltage Cur rent External Main chan...

Page 11: ...channels one to set output voltage or current and one to set the corre sponding protection limit The main channel is deter mined by the MODE key in local mode which alternately selects either Voltage...

Page 12: ...ral Setup menu then highlight Max Min Set tings 2 Press to enter the Max Min Settings submenu Figure 6 If a Password is required see Opera tor s Manual for instructions 3 Highlight the voltage or curr...

Page 13: ...afety fea tures constant current type active electronic loads must be adjusted to zero and the BOP front panel LCD must read 0V minimum cur rent before handling the power supply to load connections Re...

Page 14: ...flow during the OFF state Table 5 indicates how the power supply responds to a command to go from Output ON to OFF CONFIGURE LOAD TYPE To configure press from the power up screen then highlight Load T...

Page 15: ...copower com email hq kepcopower com FIGURE 1 BOP 1KW OUTLINE DIMENSIONS SHEET 1 OF 2 20 000 508 00 21 439 544 54 22 800 579 11 21 564 547 73 22 000 558 79 23 863 606 12 18 235 463 16 18 985 482 21 1 4...

Page 16: ...FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 1 BOP 1KW OUTLINE DIMENSIONS SHEET 2 OF 2 SLIDES TRAVEL DISTANCE 23 000 584 2 22 000 5...

Reviews: