 - Display

Display Settings:: Graphic Display
(

meters

/graphics, background (

black

/

white/monoblack/blue/green/lt.green/
lt.blue), Protect Entry (

independent

/bipo-

lar) Waveform Stop (

outputOFF

/User

Option), Key Press beep (

On

/Off/Error

only)

$

 - Analog Remote Setup

Analog Remote Settings: Reference input
(

internal

/external/external reference

level), protect limit (

Internal

/External/Les-

serLimit), external mode (

disable/

enable)

%

 - General Setup

Interface Settings: 

*RST set Output (

on

/off), 

GPIB Settings: Language (

SCPI

/CIIL),

GPIB address (default = 

6

),  Device

clear (

SCPI

/MATE) 

Serial Settings: Baudrate (

Off

/9600/

19200/38400), Xon/Xoff (

disable

/

enable), prompt (

disabled/echo/

enabled/enab+echo)

LAN Settings: IP Address, IP MASK,
AUTO IP 

ON

, DHCP 

ON

, Name and

index (MDNS name)

Max/Min Settings: for voltage mode: +Volt-
age max, –Voltage min, ±CProtect max/
min; for current mode: +Current max,
–Current min, ±VProtect max/min

Load Type: 

Active

/Resistive/Battery,

Remote On-off: (disabled/high is off/low is
off/high is on/low is on/LowPulseOff)

Standby Pin Operation: 

LowPulse

, HighI-

sOn, LowIsOn, HighIsOff, LowIsOff, Dis-
abled

Revisions/Test: (Tests: display, keypad,
LAN, interface, serial, analog and output)

Calibration: Voltage, Current and External
and Controls calibration. Shows Firmware
versions for Display, Serial, GPIB, LAN
and analog.

Power-up Settings: Mode (

Voltage

/Cur-

rent/External), Main channel Reference
(

Internal

/External/ExtlRefLev), main set-

ting, Protection: Type (

Internal

/External/

LesserLimit), Voltage  Limit (current mode),
Current Level (voltage mode), output 

ON

/

OFF

Password

Password Settings: Menu protection
(Interface/Max-Min/Load/Test/Calibra-
tion/Power-up/Keypad @ local/Key-
pad@power-up), Save Display Change
(Enable/

Disable

), Passwords (Unpro-

tected/Main/Admin1/Admin2)

Series/Parallel: Configuration (Standalone/
Parallel/Series/Master 2X2/Master 3X2);
for parallel or series: Unit Type (Stand-
alone/1 to+4/Slave #1 to #4) and
Configuration: shows Series or Parallel).

FIGURE 5.  POWER-UP SCREEN SHOWING GRAPHIC METERS

HOW TO MODIFY A PARAMETER. 

First access the parameter by accessing the proper
menu as described above. To modify a parameter
listed in a menu or submenu, proceed as follows:

1. Highlight the parameter using the 

Y

 and 

U

 

keys.

2. When the desired choice is highlighted, press 

!

to modify the active setting. The choices are dis-

played with the active setting highlighted. In the
case of numerals, the units digit is highlighted. 

To change a numeric setting, press the num-
ber keys, then press 

ENTER

 to program the

numbers entered. Use the 

CLEAR key

 to

clear numbers entered and start over. The

ADJUST 

control can also be used to incre-

ment or decrement the highlighted digit.

Summary of Contents for BOP 10-100MG/ME

Page 1: ...units the GPIB interface is replaced with a LAN interface Unless otherwise noted this guide applies to both models ACCESSING MANUALS First determine your Firmware Version see below then download the B...

Page 2: ...or current and a 1 to 10V input for the limit channels BOP models are suitable for driving inductive loads such as large magnets or motors and for exercising batteries They are also suitable for chara...

Page 3: ...el 1 d c Output Range Closed Loop Gain Output Impedance Voltage 2 V d c Current A d c Voltage Channel GV V V Current Channel GI A V Voltage Mode Series R L Current Mode Parallel R C Rd c mOhms L H Rd...

Page 4: ...4 228 1692 REV 8 090418 KEPCO INC 131 38 SANFORD AVENUE FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 1 BOP OUTPUT CHARACTERISTICS...

Page 5: ...n to IEEE 1118 BITBUS port 142 0485 Kepco KMDLA 5P Kycon Inc IEEE 488 Cable 1 meter long For MG models only Connects BOP power supply to GPIB bus SNC 488 1 IEEE 488 Cable 2 meter long For MG models on...

Page 6: ...operation voltage or current output volt age or current and establish positive and negative voltage and current limits An output analog corre sponding to output current is also provided Refer to Oper...

Page 7: ...LS AND INDICATORS RS 232 CONNECTIONS Connect the BOP 1KW to a modem using a Null Modem patch cable at the RS 232 port located on the rear panel See Fig ure 3 A Null Modem cable is not required for old...

Page 8: ...1355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 3 BOP 1KW SERIES REAR PANEL VIEW LINKS INSTALLED FOR LOCAL SENSING FIGURE 4 LOAD CONNECTION A LOCAL...

Page 9: ...ng an item on the list and pressing the View Modify function key Menus and submenus will display a list of parameters with the top one high lighted The function key assignments can vary but generally...

Page 10: ...g and output Calibration Voltage Current and External and Controls calibration Shows Firmware versions for Display Serial GPIB LAN and analog Power up Settings Mode Voltage Cur rent External Main chan...

Page 11: ...channels one to set output voltage or current and one to set the corre sponding protection limit The main channel is deter mined by the MODE key in local mode which alternately selects either Voltage...

Page 12: ...ral Setup menu then highlight Max Min Set tings 2 Press to enter the Max Min Settings submenu Figure 6 If a Password is required see Opera tor s Manual for instructions 3 Highlight the voltage or curr...

Page 13: ...afety fea tures constant current type active electronic loads must be adjusted to zero and the BOP front panel LCD must read 0V minimum cur rent before handling the power supply to load connections Re...

Page 14: ...flow during the OFF state Table 5 indicates how the power supply responds to a command to go from Output ON to OFF CONFIGURE LOAD TYPE To configure press from the power up screen then highlight Load T...

Page 15: ...copower com email hq kepcopower com FIGURE 1 BOP 1KW OUTLINE DIMENSIONS SHEET 1 OF 2 20 000 508 00 21 439 544 54 22 800 579 11 21 564 547 73 22 000 558 79 23 863 606 12 18 235 463 16 18 985 482 21 1 4...

Page 16: ...FLUSHING NY 11355 U S A TEL 718 461 7000 FAX 718 767 1102 http www kepcopower com email hq kepcopower com FIGURE 1 BOP 1KW OUTLINE DIMENSIONS SHEET 2 OF 2 SLIDES TRAVEL DISTANCE 23 000 584 2 22 000 5...

Reviews: