3-3 Setup Procedure For The Unit (continued)
SETTING
PRESET B
PRESS
DISPLAY
B
PRESET B
PRE B Button.
Enters Preset Routine.
Flashing PRESET B
number.
CLR
0 Flashes.
Clears out existing PRESET B.
1 2 3 4
1234 PRESET B
Flashes.
Sample Preset.
ENT
Last count, unit now in run
Store new Preset.
mode.
Preset B is Set.
MENU ITEM 1
DEV TYP
This menu item is used to set up the ratemeter and
totalizers. Please refer to the K Factor worksheets
(Section 7) or other notes you may have prepared.
Setting the Ratemeter.
PRESS
DISPLAY
D Menu Button
DEV TYP
↓
ENT
RT
↓
CNT
↓
Enters routine to program the Ratemeter or
Counter.
B
K FACT A
This selects the Ratemeter portion of the unit.
K FACT A flashes then shows the current rate K
Factor for input A.
CLR
0 Flashes.
Clears out existing A K FACTOR.
1 2 D 0 5 6
12.056 Flashes.
Sample K Factor, or enter calculated value from
notes or worksheet.
ENT
K FACT B
We are still in the Ratemeter portion of the unit.
K FACT B flashes then shows the current rate K
Factor for input B.
CLR
0 Flashes.
Clears out existing B K FACTOR.
7 6 D 2 8
76.28 Flashes.
Sample K Factor, or enter calculated value from
notes or worksheet.
ENT
WEIGHT #.#
Store new K Factor.
The weight is a multiplier assigned to the old rate
that is averaged with the new sampled rate to
prevent erratic change. A 0.0 setting shows the
new rate immediately. A 9.9 setting averages the
new sampled rate with 9.9 times of old displayed
rate. (See section 3-5 Internal Operation.)
CLR
WEIGHT 0.0
Clears out existing WEIGHT number value.
7 0
WEIGHT 7.0
As an example, averages 7X old rate with new
rate.
ENT
WINDOW ##
Store new Weight.
The window sets the minimum rate sampling
time (02 to 24 sec). The unit accumulates the
input pulses for the