Page 9
3-3 Setup Procedure For The Unit (continued)
window amount of time and calculates the
averaged rate. The selected "weight" is then
averaged in. The display is updated after each
rate sample.
PRESS
DISPLAY
CLR
WINDOW 00
Clears out existing WINDOW number value.
5
WINDOW 05
As an example, extends the window to 5 seconds.
ENT
SIG FIG ##
Store new WINDOW.
SIG FIG indicates how many meaningful
digits are shown. For example, if SIG FIG is
set at three; a rate of 24737.89 will be displayed
as 24700; a rate of 0.739216 will be displayed as
0.739. Note that trailing zeroes will be inserted
only if necessary. Digits beyond the SIG FIG
value are truncated and zeroes are inserted as
needed, no rounding is done.
CLR
SIG FIG 00
Clears out existing SIG FIG number value.
4
SIG FIG 04
As an ex., display will show only 4 significant
figures.
ENT
Last count, unit now in
Store new SIG FIG. Run Mode.
The Ratemeter portion of The Unit is now setup.
The next thing to do, is to set up the counter
portion of the unit. This requires going back into
the menu to DEV TYP.
MENU ITEM 1
DEV TYP (continued)
This menu item is used to set up the ratemeter and
totalizers. Please refer to the K Factor worksheets
(Section 7) or other notes you may have prepared.
Setting the Counter.
PRESS
DISPLAY
D
DEV TYP
↓
Menu Button.
ENT
RT
↓
CNT
↓
Enters routine to program the Ratemeter or
Counter.
D
K FACT A
This selects the Counter portion of the unit.
K FACT A flashes then shows the current A K
Factor.
CLR
0 Flashes.
Clears out existing A K FACTOR.
3 7 D 6
37.6 Flashes.
Sample A K Factor, or enter calculated value
from notes or worksheet.
ENT
K FACT B
This selects the Counter portion of the unit.
K FACT B flashes then shows the current B K
Factor.
CLR
0 Flashes.
Clears out existing B K FACTOR.
6
6 Flashes.
Sample B K Factor, or enter calculated value
from notes or worksheet.
ENT
A+B
↓
Store new B K Factor.
Summary of Contents for KEPtrol F/C