8-11 Strobe Address Operation
Another method of reading the status of a unit
with either a RS232 or RS422 option is by means
of a separate strobe address and a 3 bit data
request code. The strobe address method does
not allow changes of set points. Theoretically
hundreds of units could be linked together to
transmit data from The Unit over a serial
transmit line. The units could be assigned any
code number except "00".
The 3 bit data request code would be latched in at
the positive edge of a 3 to 30 VDC strobe input
that remained high a minimum of 25
milliseconds. Requests are processed on a non-
priority basis. Normally data will begin to be
transmitted from The Unit over the RS232 or
RS422 serial transmit lines within 5 msec unless
interrupted by a keypad entry or other signal
input.
Note: No other unit should be brought on line
until data requested has been transmitted.
8-11.1 Strobe Input Codes
# DL4 DL2 DL1
Code Description
0 0
0
0
PA
Transmits Preset A value.
1 0
0
1
PB
Transmit Preset B value.
2 0
1
0
KA
Transmits K Factor counter A.
3 0
1
1
KB
Transmits K Factor counter B.
4 1
0
0
KC
Transmits K Factor rate A.
5 1
0
1
KD
Transmits K Factor rate B.
6 1
1
0
DR
Will transmit Rate.
7 1
1
1
DC
Will transmit Count.
CONCLUSION
This manual has attempted to cover all aspects of
operation of The Unit. It is written to cover most
anticipated problems and misunderstandings. If
some questions still arise, or you feel some
improvements can be made to this manual, please
feel free to contact your local Representative.
Decoding Part Number
EX:
KF/C8
A
3A
2
A
2
Series
KEPtrol F/C
Operating Voltage
A: 110 VAC
±
15% or 12 to 27 VDC
B: 220 VAC
±
15% or 12 to 27 VDC
Control Inputs
*3A: STD High Impedance
Pulse 3-30 VDC, 20KHz Max.
*3B: same as 3A with 4.7 K
Ω
pull up resistors
Control Outputs
1: Open Collector
2: SPDT Relay 10 A
Input Speed
*A: 0-40 CPS
*C: 0-400 CPS
*E: 0-10K CPS
* Dip switch selectable, all units can be field
modified easily.
Options
1: RS232 Serial Interface
2: RS422 Serial Interface
3: 4-20 mA Output
Accessories
NEMATROL 4X1 - NEMA 4X Enclosure for
wall mounting accommodating 1 'trol Series
unit.
NEMATROL 4X2 - NEMA 4X Enclosure for
wall mounting accommodating 2 'trol Series
unit.
FLEXCOVER #30120
Clear membrane for front panel. Prevents
dirt build up on buttons.
WARRANTY
This product is warranted against defects in materials and work-
manship for a period of two (2) years from the date of shipment to
Buyer.
The Warranty is limited to repair or replacement of the defective
unit at the option of the manufacturer. This warranty is void if the
product has been altered, misused, dismantled, or otherwise
abused.
ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, ARE
EXCLUDED, INCLUDING BUT NOT LIMITED TO THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE.
Summary of Contents for KEPtrol F/C
Page 4: ...THIS PAGE IS BLANK...