KEOFITT W9 USER MANUAL V.4
PAGE 9
Spores
Relatively water-poor resting cells surrounded by an impervious cell wall,
which makes them relatively resistant to disinfectants and sterilants. They
are dangerous as they can survive in adverse conditions and re-emerge as
live bacteria at a later stage.
Sporicidal
The property of an agent that kills spores.
Steaming
The process of using saturated steam under pressure as the sterilising agent.
Sterile
State of being free from all living microorganisms. In practice, usually
described as a probability function, e.g., as the probability of any
microorganism surviving sterilisation being one in one million.
Sterilant
A few disinfectants will kill spores with prolonged exposure times (3–12
hours); these are called chemical sterilants.
Sterilisation
Validated process used to render an item free of all forms of viable
microorganisms. In a sterilisation process, the presence of microorganisms is
expressed in terms of probability. Although this probability can be reduced to
a very low number, it can never be reduced to zero.
Sterility Assurance Level The probability of a viable microorganism being present on an item after
sterilisation. Usually expressed as 10
–n
; a SAL of 10
-6
means <1/1 million
chance that a single viable microorganism is present on a sterilised item.
Tensides
A tenside is a surfactant that reduces the surface tension of water and
assures a faster and better contact between the detergent and the soil.
1.2 Quick start
The table below gives you an overview of the relevant chapters to read depending on the operations you
want to perform to obtain the required hygienic level.
Required
hygienic level
4.1 Pr
e-
pr
oduction
tr
eatment
4.2 Chemic
al
cle
aning CIP
4.3 Chemic
al
disinf
ection
4.4 St
eaming
5.1 Chemic
al
CIP
5.2 Chemic
al
disinf
ection
5.3 St
eam
st
erilisation
5.4 Sampling
Cleaning
Disinfection
Sterilisation
Summary of Contents for W9
Page 1: ...DON T GAMBLE WITH YOUR SAMPLE W9 SAMPLING VALVE User Manual ...
Page 4: ...KEOFITT W9 USER MANUAL V 4 PAGE 4 ...
Page 44: ...KEOFITT W9 USER MANUAL V 4 PAGE 44 16 MEMBRANES 16 1 Silicone membrane art no 600051 ...
Page 45: ...KEOFITT W9 USER MANUAL V 4 PAGE 45 16 2 Silicone membrane for Micro Port art no 600251 ...
Page 46: ...KEOFITT W9 USER MANUAL V 4 PAGE 46 16 3 EPDM membrane art no 600052 ...
Page 47: ...KEOFITT W9 USER MANUAL V 4 PAGE 47 16 4 EPDM membrane for Micro Port art no 600252 ...
Page 48: ...KEOFITT W9 USER MANUAL V 4 PAGE 48 16 5 FFKM membrane art no 600053 ...
Page 49: ...KEOFITT W9 USER MANUAL V 4 PAGE 49 16 6 PTFE membrane art no 850055 ...