Contact time
The time span during which the item is in contact with the detergent or the
disinfectant.
Enzymes
Molecules, which are added to cleaning agents to ease the removal
of specific organic material. Assures same cleaning effect at a lower
temperature.
Disinfectant
Usually a chemical agent that destroys harmful microorganisms but might
not kill bacterial spores.
Disinfection
Thermal or chemical destruction of microorganisms. Disinfection is
less lethal than sterilisation, because it destroys most recognised
microorganisms but not necessarily all microbial forms (e.g. bacterial
spores).
Detergent
A cleaning agent that has no antimicrobial effect, but in diluted solutions
good cleaning properties.
EHEDG
Abbreviation for the European Hygiene Engineering and Design Group.
EHEDG is a consortium of equipment manufacturers, food industries,
research institutes as well as public health authorities promoting safe
food by improving hygienic engineering and design in all aspects of food
manufacture.
Electro polishing
Electro polishing is an electrochemical process by which the high points
within the microscopic surface texture are removed and the corners rounded.
This results in Reduced Product Adhesion, Ease of Cleaning and Improved
Corrosion Resistance.
Exposure time
Period in a sterilisation/disinfection process during which the item is
exposed to the sterilant/disinfectant at the specific sterilisation/disinfection
parameters.
Flow path
The path the sample flows from the tank or process equipment to the sample
recipient.
Germicidal
The property of an agent to destroy microorganisms.
Microbial load
The number and types of viable microorganisms with which an item is
contaminated; also called bioload or bioburden.
Microorganisms
Animals or plants of microscopic size. As used in food and pharmaceutical
industries, generally refers to bacteria, fungi, viruses and bacterial spores.
Peracetic acid
A commonly used disinfectant, which is efficient at low temperature and
short contact time. Relatively harmless as it decomposes into carbon dioxide
(CO
2
) and water (H
2
O).
Process media
The product in the process equipment and the product from which a sample
is taken.
Representative sample A sample which when it reaches the laboratory is still identical to the process
media. A sample which is in no way contaminated or altered during neither
the sampling process nor the transport to the laboratory.
Sanitization
The application of a chemical agent that reduces the number of bacterial
contaminants to a safe level as judged by the public health authorities. The
official sanitizer protocol indicates that 99.999% of the specific test bacteria
be killed in 30 seconds under the conditions of the test.
SIP
Abbreviation for Sterilise-In-Place. The process of rendering a process
component (like a sampling valve) sterile without removing it from the
production line.
Summary of Contents for W9
Page 1: ...DON T GAMBLE WITH YOUR SAMPLE W9 SAMPLING VALVE User Manual ...
Page 4: ...KEOFITT W9 USER MANUAL V 4 PAGE 4 ...
Page 44: ...KEOFITT W9 USER MANUAL V 4 PAGE 44 16 MEMBRANES 16 1 Silicone membrane art no 600051 ...
Page 45: ...KEOFITT W9 USER MANUAL V 4 PAGE 45 16 2 Silicone membrane for Micro Port art no 600251 ...
Page 46: ...KEOFITT W9 USER MANUAL V 4 PAGE 46 16 3 EPDM membrane art no 600052 ...
Page 47: ...KEOFITT W9 USER MANUAL V 4 PAGE 47 16 4 EPDM membrane for Micro Port art no 600252 ...
Page 48: ...KEOFITT W9 USER MANUAL V 4 PAGE 48 16 5 FFKM membrane art no 600053 ...
Page 49: ...KEOFITT W9 USER MANUAL V 4 PAGE 49 16 6 PTFE membrane art no 850055 ...