KEOFITT W9 USER MANUAL V.4
PAGE 25
1. Open the valve slowly and take the sample.
NB! In order to flush the valve seat before sampling you may choose
to let the first few seconds of flow go to drain.
2. Close the valve after the sample has been taken.
3. Clean the valve by flushing with steam, water or hot water.
If the process media is sticky, viscous or aggressive or for any other appropriate reason, do repeat a full
CIP cycle after sampling in case steam is not available and flushing with water prove insufficient.
WARNING
• When sampling at a high pressure and/or with a low viscosity process media it may flow rapidly
into the sample recipient. Therefore open the valve slowly. Special care must be taken with
pneumatically operated valves, as they open abruptly. If problematic, consider adjustable
actuators.
• Always remember to wear safety goggles when steaming, CIPping, taking samples or any other
operations of the sampling valve