SELECTING A DATA TRANSFER RATE
The default data transfer rate is 1200 bps. If your
network uses a 9600 bps transfer rate, you can change
the default setting.
1
Press
[MNU]
to enter Menu mode.
2
Press
[
c
c
c
c
c
]
/
[
d
d
d
d
d
]
to select “TNC (1–9–)”, then press
[OK]
.
3
Press
[
c
c
c
c
c
]
/
[
d
d
d
d
d
]
to select “DATA SPEED (1–9–6)”,
then press
[OK]
.
4
Press
[
c
c
c
c
c
]
/
[
d
d
d
d
d
]
to select 9600 or 1200 bps.
5
Press
[OK]
to complete the setting.
6
Press
[MNU]
to exit Menu mode.
Note:
◆
Transmit data input sensitivity is 40 mV
p-p
for 1200 bps baud rate
and 2V
p-p
for 9600 bps baud rate. Input impedance for both baud
rates is 10 k
Ω
. Using a modulator input level that is different than
these optimum specifications may result in deterioration of S/N
ratio or signal distortion, which could result in increased errors or a
complete failure to connect with other stations.
◆
The TX delay parameter on your TNC (for example, 300 ms)
should be set using your computer.
◆
Packet operation, easily affected by transmit and receive
conditions, requires a full-scale S-meter reading for reliable
communication.