47
9
1
Press
[MNU]
to enter Menu mode.
2
Press
[
c
c
c
c
c
]
/
[
d
d
d
d
d
]
to select “AUX (1–9–)”, then press
[OK]
.
3
Press
[
c
c
c
c
c
]
/
[
d
d
d
d
d
]
to select “SCAN RESUME (1–9–1)”,
then press
[OK]
.
4
Press
[
c
c
c
c
c
]
/
[
d
d
d
d
d
]
to select Time-Operated (default),
Carrier-Operated, or Seek.
5
Press
[OK]
to complete the setting.
6
Press
[MNU]
to exit Menu mode.
SELECTING SCAN RESUME METHOD
The transceiver stops scanning at a frequency (or
memory channel) on which a signal is detected. It then
continues scanning according to which resume mode
you select. You can choose one of the following modes.
The default is Time-Operated mode.
•
Time-Operated mode
The transceiver remains on a busy frequency (or
memory channel) for approximately 5 seconds, then
continues to scan even if the signal is still present.
•
Carrier-Operated mode
The transceiver remains on a busy frequency (or
memory channel) until the signal drops out. There is
a 2 second delay between signal drop-out and scan
resumption.
•
Seek mode
The transceiver remains on a busy frequency (or
memory channel) even after the signal drops out and
does not automatically resume scanning.
Note:
To temporarily stop scanning and monitor weak signals, press
the Mic PF key assigned the Monitor function {page 60}. Press the PF
key again to resume scanning.