![background image](http://html.mh-extra.com/html/kenwood/tk-5210/tk-5210_service-manual_191525060.webp)
TK-5210
(
G
)
60
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
12. VOX 1
1) Adj item: [VOX1]
Adjust:
[***]
AG: 1kHz/45mV at
MIC terminal
1) Adj item: [VOX1]
AG: 1kHz/45mV at
MIC terminal
AG
Panel
Universal
connector
Panel
[Panel tuning mode]
After apply signal
from AG, press [B]
key to store the
adjustment value.
[PC test mode]
After apply signal
from AG, press [Ap-
ply] button to store
the adjustment
value.
13. VOX 10
1) Adj item: [VOX10]
Adjust:
[***]
AG: 1kHz/3mV at
MIC terminal
1) Adj item: [VOX10]
AG: 1kHz/3mV at
MIC terminal
14. Battery
Warning
Level
writing
1) Adj item: [Battery]
Adjust:
[***]
PTT:
ON
1) Adj item: [Battery
Warning Level]
PTT: Press [Trans-
mit] button.
Power
meter
DVM
Panel
ANT
BATT
terminal
Panel
[Panel tuning mode]
After pressing the
PTT switch, confi rm
that one predeter-
mined numeric in
the range 1 to 256
appears and then
press [B] key That
numeric will be
stored in memory.
[PC test mode]
After pressing the
PTT switch, confi rm
that one predeter-
mined numeric in
the range 1 to 256
appears and then
press [Apply] key
That numeric will be
stored in memory.
BATT terminal
voltage: 5.8V
15. Battery
Warning
Level
check
[Panel test mode]
1) CH-Sig: 1-1
BATT terminal volt-
age: 6.0V
PTT:
ON
1) Test Channel: Chan-
nel 1
Test
Signaling
Mode: Analog
Signaling: 1
BATT terminal volt-
age: 6.0V
PTT: Press [Trans-
mit] button.
The transceiver
can transmit with
causing the LED to
blink.