TK-5210
(
G
)
58
ADJUSTMENT
Item
Condition
Measurement
Adjustment
Specifi cations /
Remarks
Panel tuning mode
PC test mode
Test-
equipment
Unit
Terminal
Unit
Parts
Method
6. P25 High
Deviation
*2
[Concentric SW]: C
1) Adj item: [A P25 Hi
Dev]
Adjust:
[***]
Deviation
meter
LPF: 3kHz
HPF: OFF
2) Adj item: [L]
→
[LC]
→
[C]
→
[CH]
→
[H]
Adjust:
[***]
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [P25 High
Deviation]
Deviation
meter
LPF: 3kHz
HPF: OFF
2) Adj item: [Frequen-
cy]
[Low]
→
[Low’]
→
[Center]
→
[High’]
→
[High]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
Deviation
meter
Oscilloscope
Panel
ANT
Panel
[Panel
tuning
mode]
[C],[D]
[PC
test
mode]
[ ],[ ]
2827kHz
Set it the ad-
justment value
obtained from the
[Max Deviation
Adjust [Narrow]]
adjustment of step
2).
2771~2883Hz
7. QT Fine
Deviation
*2
[Wide]
[Concentric SW]: A
1) Adj item: [W QT
Dev]
Adjust:
[***]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [QT Fine
Deviation (Wide)]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value
Deviation
meter
Oscilloscope
Panel
ANT
Panel
[Panel
tuning
mode]
[C],[D]
[PC
test
mode]
[ ],[ ]
Write the value as
followings.
132 (Reference
value)
0.75kHz±50Hz
[Narrow]
[Concentric SW]: B
1) Adj item: [N QT
Dev]
Adjust:
[***]
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [QT Fine
Deviation (Narrow)]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
Write the value as
followings.
135 (Reference
value)
0.375kHz±50Hz
8. DQT Fine
Deviation
*2
[Wide]
[Concentric SW]: A
1
)
Adj item: [W DQT
Dev]
Adjust:
[***]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [DQT Fine
Deviation (Wide)]
Deviation
meter
LPF: 3kHz
HPF: OFF
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
Deviation
meter
Oscilloscope
Panel
ANT
Panel
[Panel
tuning
mode]
[C],[D]
[PC
test
mode]
[ ],[ ]
Write the value as
followings.
113 (Reference
value)
0.75kHz±50Hz
[Narrow]
[Concentric SW]: B
1) Adj item: [N DQT
Dev]
Adjust:
[***]
PTT:
ON
Press [B] key to
store the adjust-
ment value.
1) Adj item: [DQT Fine
Deviation (Narrow)]
PTT: Press [Trans-
mit] button.
Press [OK] button
to store the adjust-
ment value.
Write the value as
followings.
123 (Reference
value)
0.375kHz±50Hz