1-92 (No.RA020<Rev.002>)
[NXDN
Very
Narrow]
1) Adj item:
[Nv SQL]
Adjust:[***]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
SSG output:
12dB SINAD level
at Analog Narrow
-3dB
(MOD: 400Hz/
±1.2kHz)
1) Adj item:
[Open Squelch
(NXDN Very Nar-
row)]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
SSG output:
12dB SINAD level at
Analog Narrow -3dB
(MOD: 400Hz/
±1.2kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Ext.
SP
con-
nector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
6.
Low
RSSI
1) Adj item:
[An LRSSI]
Adjust:[***]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
SSG output:
-118dBm
(0.28
μ
V)
(MOD: 1kHz/
±1.5kHz)
1) Adj item:
[Low RSSI (Analog
Narrow)]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
SSG output:
-118dBm (0.28
μ
V)
(MOD: 1kHz/
±1.5kHz)
SSG
Panel ANT
Ext.
SP
con-
nector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
7.
High
RSSI
1) Adj item:
[An HRSSI]
Adjust:[***]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
SSG output:
-80dBm (22.4
μ
V)
(MOD: 1kHz/
±1.5kHz)
1) Adj item:
[High RSSI (Analog
Narrow)]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
SSG output:
-80dBm (22.4
μ
V)
(MOD: 1kHz/
±1.5kHz)
SSG
Panel ANT
Ext.
SP
con-
nector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
8.
Tight
Squelch
[Analog
Wide
5k]
1) Adj item:
[Aw SQLT]
Adjust:[***]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
SSG output:
12dB SINAD level
at Analog Narrow
+6dB
(MOD: 1kHz/
±3kHz)
1) Adj item:
[Tight Squelch (Ana-
log Wide 5k)]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
SSG output:
12dB SINAD level at
Analog Narrow
+6dB
(MOD: 1kHz/±3kHz)
SSG
Distor-
tion
meter
Oscillo-
scope
Panel ANT
Ext.
SP
con-
nector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ] key to
store the adjustment val-
ue.
[PC test mode]
After input signal from
SSG, press [Apply] button
to store the adjustment
value.
Item
Condition
Measurement
Adjustment
Specifi-
cations
/Remarks
Panel tuning mode
PC test mode
Test-
equip-
ment
Unit
Ter-
minal
Unit
Parts
Method
Summary of Contents for NX-5700
Page 106: ...MEMO ...
Page 137: ...MEMO ...