![Kenwood NX-5000 series Manual Download Page 56](http://html.mh-extra.com/html/kenwood/nx-5000-series/nx-5000-series_manual_1956164056.webp)
0
Call Format
Call Format
is the combination of A Tone, B Tone, C Tone, and D Tone the transceiver waits to receive. The following
combinations are available.
Table 1-10 List of Call Format Combinations
Combination
Description
A and B
The transceiver waits to receive A Tone and B Tone.
A and C
The transceiver waits to receive A Tone and C Tone.
A and D
The transceiver waits to receive A Tone and D Tone.
B and A
The transceiver waits to receive B Tone and A Tone.
B and C
The transceiver waits to receive B Tone and C Tone.
B and D
The transceiver waits to receive B Tone and D Tone.
C and A
The transceiver waits to receive C Tone and A Tone.
C and B
The transceiver waits to receive C Tone and B Tone.
C and D
The transceiver waits to receive C Tone and D Tone.
D and A
The transceiver waits to receive D Tone and A Tone.
D and B
The transceiver waits to receive D Tone and B Tone.
D and C
The transceiver waits to receive D Tone and C Tone.
Long A
The transceiver waits to receive A Tone.
Long B
The transceiver waits to receive B Tone.
Long C
The transceiver waits to receive C Tone.
Long D
The transceiver waits to receive D Tone.
Note
If anything other than “Long A”, “Long B”, “Long C”, or “Long D” is configured in
Call Format
, the transceiver waits to
receive the first tone for 1 sec and the second tone for 3 sec. If “Long A”, “Long B”, “Long C”, or “Long D” is configured
in
Call Format
, the transceiver waits to receive the corresponding tone for 5 or more sec.
0
Transpond/ Alert Tone
Transpond
and
Alert Tone
are functions that allow the transceiver to transmit a multiplexed Transpond tone, or that
allow an Alert Tone to sound from the transceiver when the transceiver is called with 2-tone signaling.
Table 1-11 Transpond/ Alert
Transpond
Alert
Description
No
Off
The transceiver does not respond at all.
Yes
Off
The transceiver transmits a Transpond tone.
No
Anything other
than Off
An Alert Tone sounds from the transceiver.
Yes
Anything other
than Off
An Alert Tone sounds from the transceiver after transmitting a Transpond tone.
The Alert Tone to be emitted when the transceiver is called with 2-tone signaling is selected from 8 types of tones configured
in
Alert Tone Pattern
. (Refer to Common FUNC
Configuring the Alert Tone (Alert Tone Pattern)
.)
1 P25 CONVENTIONAL SYSTEM
1.7 Using 2-tone to Initiate an Individual Call
P25 FUNC (K)/Ver 2.20
36