![Kenwood NX-5000 series Manual Download Page 218](http://html.mh-extra.com/html/kenwood/nx-5000-series/nx-5000-series_manual_1956164218.webp)
Scan is the function to check whether the transceiver receives a call from other transceivers.
The transceiver sequentially searches for availability of signal on each channel, and the transceiver receives on the channel
where the signal is detected.
The following scan methods are available:
0
Single Scan
The transceiver scans target channels in the same zone. In a P25 Trunking system, Priority Monitor Scan can be used
as the Single Scan function.
0
List Scan
The transceiver scans the Zone-channel registered as a member in a Scan List. In a P25 Trunking system, Priority
Monitor Scan and Limited Talkgroup Scan can be used as the List Scan function.
0
Multi-Zone Scan
The transceiver scans all target channels in the target zones.
Note
In a P25 Conventional system, because P25 Voting is executed for a channel with “P25 Voting with NAC” configured in
System Type
, the configuration in
Scan Type
Migrating Automatically to the Site Providing Better
Radio Environment (P25 Voting)
” for instructions on scanning by P25 Voting in a P25 Conventional system.
6.1
Starting the Scan
Scan can be started by one of the following methods:
0
Operating the PF keys
0
Pressing the
Scan
key starts or stops scanning.
0
Pressing the
Scan Normal
key starts or stops scanning.
Even if the Priority Channel is configured, pressing the
Scan Normal
key disables the Priority Channel and mandatorily
executes Non-Priority Scan.
0
Executing “Scan” or “Scan Normal” after pressing the
Menu
key to enter Menu Mode starts or stops scanning.
0
Lever Switch operation
Operating the
Concentric
switch to be in the position where “Scan” or “Scan Normal” is allocated starts scanning.
Operating the
Concentric
switch to be in the position where “Scan” or “Scan Normal” is not allocated stops scanning.
0
Status changes of the AUX Input port (Mobile only)
When the AUX Input port where “Scan” is assigned goes low level, the scan starts. When the AUX Input port where
“Scan” is assigned goes high level, the scan stops.
0
Turning the transceiver ON/ OFF
If
Power-on Scan
is enabled, the scan starts when the transceiver is turned ON. (Refer to
.)
0
Selecting a channel
The scan starts if a channel with
Auto Scan
enabled is selected. (Refer to
Configuration using KPG-D1/ D1N
0
Assigning functions to the
PF
keys on the transceiver (
Transceiver Settings > Key Assignment)
0
Allocating functions to the
Lever
switch (
Transceiver Settings > Key Assignment > Top/Side)
0
Allocating functions to the AUX Input port (
Extended Function > AUX)
6 SCAN
6
SCAN
P25 FUNC (K)/Ver 2.20
198