Emergency Alarm
Emergency Alarm
is the function to send an Emergency Alarm Request message before the transceiver enters Emergency
Mode to notify the base station that the transceiver is in an emergency situation.
Using this function can reliably notify the base station that the transceiver is in an emergency situation.
When the
Emergency
key is pressed or Lone Worker and various Activity Detection functions are activated, an Emergency
Alarm Request message is sent to the base station if the transceiver is in a P25 Conventional system, or to the system if
the transceiver is in a P25 Trunking system. When the transceiver receives an ACK from the base station or the system,
“Ack Received” appears on the display and the transceiver enters Emergency Mode.
If the transceiver cannot receive the ACK after sending the Emergency Alarm Request message, the transceiver resends
the Emergency Alarm Request message. If the transceiver still cannot receive the ACK after sending the Emergency Alarm
Request message 5 times, the transceiver enters Emergency Mode.
Note
If a zone or channel is changed while the transceiver is in Emergency Mode, the transceiver sends the Emergency Alarm
Request message on the new channel.
Configuration using KPG-D1/ D1N
0
Configuring
Emergency Alarm
(P25 Conventional) to be enabled or disabled (
Transceiver Settings > Personal
> Personal Features > P25 Conventional (P25 Voting with NAC) > Emergency)
0
Configuring
Emergency Alarm
(P25 Trunking) to be enabled or disabled (
Transceiver Settings > Personal >
Personal Features > P25 Trunking > Emergency)
Emergency Talkgroup (P25 Trunking System Only)
Emergency Talkgroup
is the Talkgroup ID used in Emergency Mode in a P25 Trunking system.
The transceiver behaves as follows according to the configuration in
Emergency Talkgroup
of the system where
Emergency Channel belongs to:
0
If the List Number of Emergency Talkgroup is configured “None”
When the transceiver is in Emergency Mode, the transceiver executes the Emergency behavior by using the Talkgroup
ID configured in Emergency Channel.
0
If the List Number of Emergency Talkgroup is configured anything other than “None”
When the transceiver is in Emergency Mode, the transceiver executes the Emergency behavior by using the Talkgroup
ID of the specified Talkgroup list number.
Note
If a Zone-channel is changed while the transceiver is in Emergency Mode, the transceiver sends or receives Emergency
according to the configuration in Emergency Talkgroup configured in the system of the new channel.
Configuration using KPG-D1/ D1N
Configuring
List Number
(
Transceiver Settings > Personal > Personal Features > P25 Trunking > Emergency >
Emergency Talkgroup)
3 COMMUNICATIONS IN AN EMERGENCY
3.1 Placing the Transceiver in Emergency Mode
P25 FUNC (K)/Ver 2.20