(No.RA054<Rev.001>)1-85
[DSP
(Standby)]
1) Adj item:
[An RSSI 3]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[C2]
→
[H1]
→
[H3]
SSG output:
12dB SINAD
level -3dB
(MOD:
1kHz/±1.5kHz)
1) Adj item:
[RSSI Reference
(Analog Narrow)
3 DSP (Standby)]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
SSG output:
12dB SINAD level
-3dB
(MOD:
1kHz/±1.5kHz)
SSG
Distortion
meter
Oscilloscope
Panel ANT
Ext. SP
connector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ]
button to store the
adjustment value.
[PC test mode]
After input signal from
SSG,
1) Press [Acquire
Monitored Value]
button.
2) Press [Apply]
button to store the
adjustment value.
[RF IC
(Standby)]
1) Adj item:
[An RSSI 4]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[C2]
→
[H1]
→
[H3]
SSG output:
12dB SINAD
level -3dB
(MOD:
1kHz/±1.5kHz)
1) Adj item:
[RSSI Reference
(Analog Narrow)
4 RF IC (Standby)]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
SSG output:
12dB SINAD level
-3dB
(MOD:
1kHz/±1.5kHz)
SSG
Distortion
meter
Oscilloscope
Panel ANT
Ext. SP
connector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ]
button to store the
adjustment value.
[PC test mode]
After input signal from
SSG,
1) Press [Acquire
Monitored Value]
button.
2) Press [Apply]
button to store the
adjustment value.
4. Squelch
Open
[Analog
Wide 5k]
1) Adj item:
[Aw SQL]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[C2]
→
[H1]
→
[H3]
SSG output:
12dB SINAD
level -3dB
(MOD: 1kHz/
±3kHz)
1) Adj item:
[Squelch Open
(Analog Wide 5k)]
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
SSG output:
12dB SINAD level
-3dB
(MOD: 1kHz/
±3kHz)
SSG
Distortion
meter
Oscilloscope
Panel ANT
Ext. SP
connector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ]
button to store the
adjustment value.
[PC test mode]
After input signal from
SSG,
1) Press [Acquire
Monitored Value]
button.
2) Press [Apply]
button to store the
adjustment value.
Item
Condition
Measurement
Adjustment
Specifica
tions
/Remarks
Panel tuning
mode
PC test mode
Test-
equipment
Unit Terminal Unit
Parts
Method
Summary of Contents for NX-3720