1-150 (No.RA054<Rev.001>)
[NXDN
Very
Narrow]
1) Adj item:
[Nv SQL]
Adjust:[****]
2) Adj item:
[L1]
→
[L5]
→
[C3]
→
[H2]
→
[H6]
SSG output:
12dB SINAD
level at Analog
Narrow
-2dB
(MOD: 400Hz/
±1.5kHz)
1) Adj item:
[Squelch Open
(NXDN Very
Narrow)]
2) Adj item:
[Low1]
→
[Low5]
→
[Center3]
→
[High2]
→
[High6]
SSG output: 12dB
SINAD level at
Analog Narrow
-2dB
(MOD: 400Hz/
±1.5kHz)
SSG
Distortion
meter
Oscilloscope
Panel ANT
Ext. SP
connector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ]
button to store the
adjustment value.
[PC test mode]
After input signal from
SSG,
1) Press [Acquire
Monitored Value]
button.
2) Press [Apply]
button to store the
adjustment value.
[DMR]
1) Adj item:
[D SQL]
Adjust:[****]
2) Adj item:
[L1]
→
[L5]
→
[C3]
→
[H2]
→
[H6]
SSG output:
12dB SINAD
level at Analog
Narrow
-4dB
(MOD: 400Hz/
±1.8kHz)
1) Adj item:
[Squelch Open
(DMR)]
2) Adj item:
[Low1]
→
[Low5]
→
[Center3]
→
[High2]
→
[High6]
SSG output: 12dB
SINAD level at
Analog Narrow
-4dB
(MOD: 400Hz/
±1.8kHz)
SSG
Distortion
meter
Oscilloscope
Panel ANT
Ext. SP
connector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ]
button to store the
adjustment value.
[PC test mode]
After input signal from
SSG,
1) Press [Acquire
Monitored Value]
button.
2) Press [Apply]
button to store the
adjustment value.
5.
Squelch
Tight
[Analog
Wide 5k]
1) Adj item:
[Aw SQLT]
Adjust:[****]
2) Adj item:
[L1]
→
[L5]
→
[C3]
→
[H2]
→
[H6]
SSG output:
12dB SINAD
level +6dB
(MOD: 1kHz/
±3kHz)
1) Adj item:
[Squelch Tight
(Analog Wide 5k)]
2) Adj item:
[Low1]
→
[Low5]
→
[Center3]
→
[High2]
→
[High6]
SSG output:
12dB SINAD level
+6dB
(MOD: 1kHz/
±3kHz)
SSG
Distortion
meter
Oscilloscope
Panel ANT
Ext. SP
connector
Panel
[Panel tuning mode]
After input signal from
SSG, press [ ]
button to store the
adjustment value.
[PC test mode]
After input signal from
SSG,
1) Press [Acquire
Monitored Value]
button.
2) Press [Apply]
button to store the
adjustment value.
Item
Condition
Measurement
Adjustment
Specifica
tions
/Remarks
Panel tuning
mode
PC test mode
Test-
equipment
Unit Terminal Unit
Parts
Method
Summary of Contents for NX-3720