1-70 (No.RA053<Rev.001>)
6.
Maximum
Deviation
[Analog
Wide 5k]
1) Adj item:
[Aw ADEV]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[C2]
→
[H1]
→
[H3]
Adjust:[****]
PTT : ON
Press [ ]
button to store
the adjustment
value.
1) Adj item:
[Maxmum
Deviation (Analog
Wide 5k)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
Press [Transmit]
button.
Press [OK] button
to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[+], [-]
Write fixed value “497”
for each adjustment
point.
Transmit at each
adjustment point and
check that the
deviation is between
4150Hz and 4250Hz.
Deviation meter
LPF: 15kHz
HPF: OFF
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
4150~4250Hz
[Analog
Wide 4k]
1) Adj item:
[As ADEV]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[C2]
→
[H1]
→
[H3]
Adjust:[****]
PTT : ON
Press [ ]
button to store
the adjustment
value.
1) Adj item:
[Maxmum
Deviation (Analog
Wide 4k)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
Press [Transmit]
button.
Press [OK] button
to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[+], [-]
Write fixed value “497”
for each adjustment
point.
Transmit at each
adjustment point and
check that the
deviation is between
3310Hz and 3410Hz.
Deviation meter
LPF: 15kHz
HPF: OFF
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
3310~3410Hz
[Analog
Narrow]
1) Adj item:
[An ADEV]
Adjust:[****]
2) Adj item:
[L1]
→
[L3]
→
[C2]
→
[H1]
→
[H3]
Adjust:[****]
PTT : ON
Press [ ]
button to store
the adjustment
value.
1) Adj item:
[Maxmum
Deviation (Analog
Narrow)]
Deviation meter
LPF: 15kHz
HPF: OFF
2) Adj item:
[Low1]
→
[Low3]
→
[Center2]
→
[High1]
→
[High3]
Press [Transmit]
button.
Press [Apply]
button to store the
adjustment value.
Deviation
meter
Oscilloscope
Panel ANT
Panel [Panel
tuning
mode]
[
],
[
]
[PC
test
mode]
[+], [-]
Write fixed value “497”
for each adjustment
point. Transmit at each
adjustment point and
check that the
deviation is between
2050Hz and 2150Hz.
Deviation meter
LPF: 15kHz
HPF: OFF
[Panel tuning mode]
PTT: ON
[PC test mode]
PTT: Press [Transmit]
button
2050~2150Hz
Item
Condition
Measurement
Adjustment
Specifications
/Remarks
Panel tuning
mode
PC test mode
Test-
equipment
Unit Terminal Unit
Parts
Method